Warning, Troubleshooting, Possible causes remedies – Bissell POWERSTEAMER PROHEAT PLUS 16981 User Manual

Page 15

Advertising
background image

SmartTemp

Ready Light does not illuminate.

Possible Causes

Remedies

The SmartTemp

switch is

Turn On the SmartTemp

switch.

not turned ON.
The machine Power Switch is

Both switches must be ON to activate the

not turned ON.

SmartTemp

Ready Light.

SmartTemp

Power Switch does not illuminate.

Possible Causes

Remedies

The machine Power Switch is

Turn On the SmartTemp

switch.

not turned ON.

Both switches must be ON to activate the
SmartTemp

Ready Light.

Reduced spray or no spray.

Possible Causes

Remedies

Bladder may be empty.

Refill tank with hot tap water.

SmartMix

®

Bottle may be empty.

Fill with Fiber Cleansing Formula.

The filter may be clogged.

Clean out filter, page 14.

Tanks may not be seated properly.

Turn power OFF; remove and reseat tanks.

Pump may have lost prime.

Turn power OFF; after 1 minute turn ON and
depress trigger.

The Pump Belt may be broken.

Turn the machine OFF and unplug from the outlet.
To check if a Pump Belt has broken, you will need
a flat head screwdriver. Insert the blade end
into the lower slot of the Belt Access door to release
the lower snap. If necessary, insert the blade end
into the upper slot to release the upper snap.
Examine for belt breakage. You should be able to
see the Pump Belt looped around the white pulley.
If it is broken or missing, please refer to
Part Numbers and Descriptions on page 17
before calling Consumer Services.
Complete installation instructions will accompany
the replacement belt.

15

Troubleshooting

WARNING:

To reduce the risk of
fire, electric shock or
injury unplug from
outlet before servicing.

Insert
Screwdriver
Blade Here

Lift Here