Bunn VP17B User Manual

Page 11

Advertising
background image

Page 11

SERVICE (cont.)

10860 061501

LIMIT THERMOSTAT

P1161.40

FIG. 4 LIMIT THERMOSTAT

Location:

The limit thermostat is located inside the rear of

the hood on the tank lid.

Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the blue and black wires from the limit

thermostat.

3. With an ohmmeter, check for continuity across the

limit thermostat terminals.

If continuity is present as described, the limit thermo-
stat is operating properly.
If continuity is not present as described, replace the
limit thermostat.

Removal and Replacement:
1. Remove all wires from limit thermostat terminals.
2. Carefully slide the limit thermostat out from under

the retaining clip and remove limit thermostat.

3. Carefully slide the new limit thermostat into the

retaining clip.

4. Refer to Fig. 5 when reconnecting the wires.

P1800

BLK to Terminal Block or Tank Heater Switch

BLU to BLU Lead from
Control Thermostat

FIG. 5 LIMIT THERMOSTAT TERMINALS