I product description, Ii specifications – Burnham CHG225 User Manual

Page 3

Advertising
background image

3

Table 2.2: Specifications

MODEL*

NO. OF

SECTIONS

MAXIMUM

INPUT

(BTU/hr)

MINIMUM

INPUT

(BTU/hr)

D.O.E.

HEATING

CAPACITY

(BTU/hr)

IBR NET

RATING

(BTU/hr)

AFUE (%)

VENT COLLAR

DIAMETERS (IN.)

INLET

EXHAUST

CHG150

3

150,000

30,000

135,000

117,000

93.1

4

3

CHG225

4

225,000

56,250

202,000

176,000

94.2

4

4

* MODELS SHOWN ARE FOR NATURAL GAS. ADD “LP” SUFFIX TO MODEL NUMBER SHOWN FOR PROPANE MODEL NUMBER (ie CHG225LP).

PERFORMANCE RATINGS ARE THE SAME FOR BOTH FUELS.

Figure 2.1: General Configuration

I Product Description

The CHG is an aluminum gas fired condensing boiler designed for use in forced hot water heating systems

requiring supply water temperatures of 180°F or less. This boiler may be vented vertically or horizontally with

combustion air supplied from outdoors. This boiler is not designed for use in gravity hot water systems or

systems containing significant amounts of dissolved oxygen.

II Specifications