Bernard Liners SPEC L-1.2 User Manual

Page 2

Advertising
background image

©2008 Bernard Printed in U.S.A.

Available Liners

Replacement Instructions and Service

Remove Existing Liner

Turn off power. Remove nozzle, tip, gas diffuser and insulator cap
(guns with jump liner remove neck). Lay cable straight. Grasp liner

lock which protrudes from power pin (some direct plugs may require

removal of additional components to access the liner lock) and remove

from cable assembly.

Install Replacement Liner

Insert liner into power pin with cable laying straight. Continue until liner

lock is fully seated into power pin. A twisting motion may be necessary

to seat O-ring (some direct plugs may require installation of additional

components to secure liner).
Making sure cable is straight, trim liner at the nozzle of the neck as

follows:
• DS-1 and D-1 Centerfire™ gas diffusers (used with Centerfire™

series tips) = between 5/8" and 3/4"
• 4235 and 4635 gas diffusers (used with 1500 series tips) = 3/8"

• 4335 and 4435 gas diffusers (used with 7400 or 4200 series

tips) = 1-3/8"
• D118Q gas diffusers (used with Quik Tips™) = 7/8"
• D114Q gas diffusers (used with Quik Tips™) = 3/4"
File the cut end of liner to eliminate burrs and reinstall

insulator cap, gas diffuser, tip and nozzle.
When using Jump Liner: Trim and deburr liner with

1/4” (6.4 mm) extending beyond the gun handle and

reinstall neck.

Service

Inspect for excessive wear and debris on the inside

diameter. Do not dip liner in solvents for cleaning. Liner

may be periodically blown out with shop air. Replace

with new liner when excessive wear or debris produces

poor electrode feed.

"

4

/

1

"

1

0

"

2

/

1

"

4

/

3

"

4

/

1

-

1

"

2

/

1

-

1

Standard Liners

Wire Size

Gun Amperage

Direct Plug

10' (3.05 m) 15' (4.57 m) 25' (7.62 m)

.023" - .030"

(.6 mm - .8 mm)

150A - 600A

All except Tweco 4, L-Tec

*N/A

43015

43025

Tweco 4, L-Tec

*N/A

**43015T

**43025T

.035" - .045"

(.9 mm - 1.2 mm)

150A

All except Tweco 4, L-Tec

43110

43115

43125

Tweco 4, L-Tec

*N/A

**43115T

**43125T

200A - 600A

All except Tweco 4, L-Tec

44110

44115

44125

Tweco 4, L-Tec

*N/A

**44115T

**44125T

.045" - 1/16"

(1.2 mm - 1.6 mm)

200A - 600A

All except Tweco 4, L-Tec

44210

44215

44225

Tweco 4, L-Tec

*N/A

**44215T

**44225T

5/64"

(2.0 mm)

200A - 400A

All except Tweco 4, L-Tec

*N/A

1920356

1920357

Tweco 4, L-Tec

*N/A

**†1920296 **†1920298

500A - 600A

All except Tweco 4, L-Tec

*N/A

44315

44325

Tweco 4, L-Tec

*N/A

**44315T

**44325T

3/32"

(2.4 mm)

500A - 600A

All except Tweco 4, L-Tec

*N/A

45415

45425

400A Clean-Air

All except Tweco 4, L-Tec

*N/A

†1920175

†1920177

7/64"

(2.8 mm)

600A

Air-Cooled Only

All except Tweco 4, L-Tec

*N/A

45615

45625

1/8"

(3.2 mm)

600A

Air-Cooled Only

All except Tweco 4, L-Tec

*N/A

46715

46725

Aluminum / Soft Wire Liners

Wire Size

Gun Amperage

Direct Plug

10' (3.05 m) 15' (4.57 m) 25' (7.62 m)

.035"

(.9 mm)

150A - 600A

Nylon

All except Tweco 4, L-Tec

*N/A

43015X

N/A

Tweco 4, L-Tec

*N/A

**43015XT

200A - 600A

Steel Coil

All except Tweco 4, L-Tec

*N/A

1920343

N/A

Tweco 4, L-Tec

*N/A

**1920346

3/64"

(1.2 mm)

200A - 600A

Nylon

All except Tweco 4, L-Tec

*N/A

43115X

N/A

Tweco 4, L-Tec

*N/A

**43115XT

200A - 600A

Steel Coil

All except Tweco 4, L-Tec

*N/A

1920344

1920350

Tweco 4, L-Tec

*N/A

**1920347

N/A

1/16"

(1.6 mm)

200A - 600A

Nylon

All except Tweco 4, L-Tec

*N/A

44215X

N/A

Tweco 4, L-Tec

*N/A

**44215XT

200A - 600A

Steel Coil

All except Tweco 4, L-Tec

*N/A

1920345

1920351

Tweco 4, L-Tec

*N/A

**1920348

N/A

*10' (3.05 m) liner not available. Order 15' (4.57 m) liner and trim to size.

†Liners without outer jacket.

**For use only with Bernard guns with Tweco 4 or L-Tec direct plugs manufactured prior to 2008.

Advertising