6— cooling capacities (mbtuh), Shc correction factor – Bryant FAN COIL UNITS FF1DNA User Manual

Page 6

Advertising
background image

—6—

COOLING CAPACITIES (MBtuh)

* Saturated suction leaving evaporator coil.

COIL REFRIGERANT TEMPERATURE* (°F)

UNIT

SIZE

EVAPORATOR

AIR

CFM and

BF

35

40

45

50

55

Evap Air—Entering Wet-Bulb Temp (°F)

72

67

62

72

67

62

72

67

62

72

67

62

72

67

62

018

400

27

23

19

25

20

16

22

17

13

19

14

10

15

10

8

0.08

13

14

15

12

13

13

10

11

12

9

10

10

8

8

8

500

30

25

21

28

22

18

24

19

15

21

15

12

16

11

10

0.10

14

16

17

13

14

16

12

13

14

10

11

12

9

10

10

600

33

27

22

30

24

19

26

21

16

23

17

13

18

12

11

0.13

15

17

19

14

16

18

13

14

16

11

13

13

10

11

11

650

34

28

23

31

25

20

27

21

17

23

17

14

18

13

12

0.14

16

18

20

14

17

18

13

15

16

12

13

14

10

11

12

024

600

38

32

26

35

29

22

31

24

18

26

19

14

21

13

12

0.05

18

20

21

16

18

19

15

16

17

13

14

14

11

11

12

700

41

34

28

38

30

24

33

26

20

28

20

16

22

15

13

0.06

19

21

23

18

19

21

16

18

19

14

15

16

12

13

13

875

46

38

31

41

34

27

37

29

22

31

23

19

25

17

16

0.08

21

24

27

20

22

24

18

20

22

16

18

19

14

15

16

030

750

46

38

31

41

33

26

36

28

21

30

22

17

24

16

14

0.04

21

23

25

19

21

22

17

19

20

15

16

17

12

13

14

900

50

42

34

46

37

29

40

31

23

33

25

19

26

18

16

0.06

23

26

28

21

23

25

19

21

22

17

18

19

14

15

16

1075

54

45

37

49

40

32

43

34

26

37

27

22

29

19

18

0.07

25

28

31

23

26

28

21

23

25

18

21

22

16

17

18

Sensible Heat Capacity (1000 Btuh)

Gross Cooling Capacity (1000 Btuh)

BF

—Bypass Factor

NOTES:

1. Net capacities shown include a deduction for evaporator fan motor heat.

2. Contact manufacturer for cooling capacities at conditions other than

shown in table.

3. Formulas:

Leaving db = entering db —

Leaving wb = wb corresponding to enthalpy of air leaving coil (h

lwb

)

h

lwb

= h

ewb

where h

ewb

= enthalpy of air entering coil.

4. Direct interpolation is permissible. Do not extrapolate.

5. SHC is based on 80°F db temperature of air entering coil. Below 80°F

subtract (corr factor x CFM) from SHC.
Above 80°F db, add (corr factor x CFM) to SHC.

SHC CORRECTION FACTOR

sensible heat cap.

1.09 x CFM

total capacity (Btuh)

4.5 x CFM

BYPASS
FACTOR

ENTERING AIR DRY-BULB TEMP (°F)

79

78

77

76

75

Under 75

81

82

83

84

85

Over 85

Correction Factor

0.10
0.20
0.30

0.98
0.87
0.76

1.96
1.74
1.53

2.94
2.62
2.29

3.92
3.49
3.05

4.91
4.36
3.82

Use formula

shown below

Interpolation is permissible.
Correction Factor = 1.09 x (1 – BF) x (db – 80)

OPTIONAL FIELD-INSTALLED ELECTRIC HEAT PACKAGES FOR FF1DNA AND FF1DNE

* Heater capacities shown here are for the largest size fan coil unit, and they do include blower motor heat.

HEATER PART NUMBER

WITH TDR

SIZE

USED

WITH

NOMINAL

KW @

240V

HEATER

VOLTS—PHASE

(60 Hz)

HEATER

CAPACITY

(MBH)*

APPROX

SHIP.

WEIGHT

(lbs)

208V

230V

KFDEH0801D05

All

5

208/230—1

14.3

17.2

7

KFDEH0901D75

All

7.5

208/230—1

20.7

25.0

7

KFDEH1001D11

All

11

208/230—1

29.7

36.0

7

Advertising