Sidekick – Bock Water heaters SideKick 199SK User Manual

Page 2

Advertising
background image

www.bockwaterheaters.com

110 South Dickinson Street , Madison, Wisconsin 53703

Toll Free 800.794.2491

Phone 608.257.2225

Fax 608.257.5304

80021 Rev 11/07

G

Cold Inlet,

3/4" NPT

Hot Outlet/

Anode Rod,

3/4" NPT

Anode Rod

Aquastat

T&P Relief Valve

From Boiler, 1" NPT

To Boiler,

1" NPT

Drain Valve

F

D

C

E

B

A

30, 40 & 50SK

G

h

A

E

F

D

C

B

Cold Inlet, 1" NPT

Hot Outlet,

1-1/2" NPT

Anode Rod

Anode

Rod

T&P Relief Valve

From Boiler,

1" NPT

To Boiler,
1"NPT

Drain Valve

Aquastat

80 & 119SK

Model

Dimensions

Shipping

Weight

(lbs)

A

B

C

D

E

F

G

H

30SK

22”

35 3/4”

27 3/4”

19 1/2”

11 3/4”

6 1/2”

4 1/2”

N/A

180

40SK

22”

42 3/4”

34 3/4”

31 1/2”

16 3/4”

6 1/2”

4 1/2”

N/A

226

50SK

22”

48 3/4”

39 3/4”

31 1/2”

16 3/4”

6 1/2”

4 1/2”

N/A

231

80SK

24”

64 3/4”

57 1/8”

33”

19 1/4”

8”

5”

5”

297

119SK

28”

65 1/4”

57 3/4”

33 3/4”

16 1/4”

8 3/4”

5”

6 1/2”

397

FIRST HOUR RATING (gal) @ Coil Output (Btu/hr)

Model

Actual Tank

Volume (gal)

First Draw

(gal)

Heat Source

Friction Loss*

(ft. w.c.)

180° F

8 GPM**

180° F

10 GPM**

180° F

12 GPM**

200° F

8 GPM**

200° F

10 GPM**

200° F

12 GPM**

30SK

30

25

2

110 @ 55,000

114 @ 57,000

117 @ 59,000

132 @ 69,000

136 @ 71,000

139 @ 73,000

40SK

38

33

3

153 @ 77,000

165 @ 84,000

177 @ 92,000

183 @ 96,000

195 @ 104,000 207 @ 111,000

50SK

45

40

3

160 @ 77,000

172 @ 84,000

184 @ 92,000

190 @ 96,000

202 @ 104,000 214 @ 111,000

80SK

75

70

5

200 @ 83,000

212 @ 91,000

224 @ 98,000

233 @ 104,000 245 @ 112,000 257 @ 119,000

119SK

110

102

5

232 @ 83,000

244 @ 91,000

256 @ 98,000

265 @ 104,000 277 @ 112,000 289 @ 119,000

All data obtained through testing in accordance with GAMA INDIRECT-FIRED WATER HEATER TESTING STANDARD IWH-TS-1_MARCH 2003

* At 8 GPM

** Coil Input (temperature, flow rate). Ratings based on 77°F rise with 58°F inlet potable water.

Note: First Hour Rating = First Draw + Continuous Draw

Warning: Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 54 or ANSI Z.21.10.1.

Caution: The recommended maximum hot water termperature setting for normal residential use is 120°F. Bock recommends a tempering valve or

anti-scald valve be installed and used according to the manufacturer’s directions to prevent scalding.

Pressures (all): Working pressure, 150 psi; testing pressure, 300 psi

Standard Voltage (all): 120V, 60 Hz, 1P

SideKick