Black & Decker 641915-00 User Manual

Page 16

Advertising
background image

16

PROBLEM

CAUSE

CORRECTION

It is normal for "some"
pressure drop to occur.

If there is an excessive
amount of pressure drop
when the accessory is used,
adjust the regulator following
the instructions in the
"Description of Operation"
paragraph in the "Operation
Section.

NOTE: Adjust the regulated
pressure under flow
conditions (while accessory
is being used).

Compressor is
not supplying
enough air to
operate
accessories.

Prolonged excessive use of
air.

Compressor is not large
enough for air requirement.

Hole in hose.

Air leaks.

Decrease amount of air
usage.

Check the accessory air
requirement. If it is higher
than the SCFM or pressure
supplied by your air
compressor, you need a
larger compressor.

Check and replace if
required.

Tighten fittings.

Pressure reading
on the regulated
pressure gauge
drops when an
accessory is
used.

Condensation in tank

Drain tank

Excessive
"auto" starting
and stopping

Possible defect in safety
valve.

Operate safety valve
manually by pulling on ring.
If valve still leaks, it should
be replaced.

Air leak from
safety valve.

641915-00,FSCP200 Compressor 3/14/06 7:31 AM Page 16

Advertising
This manual is related to the following products: