Mc-50 – BEA Two MC50s Interlocking 4 Doors User Manual

Page 2

Advertising
background image

PH: (412) 249-4100 FAX: (412) 249-4101

B.E.A., Inc.

100 Enterprise Drive, Pittsburgh, PA 15275

DATE:

REV:

DRAWN BY:

SHEET:

1 OF 1

SCALE:

NONE

SIZE: CAGE CODE:

DWG NO:

FILE OF:

ENG'G

02 JAN 04

JED

A

CMN 6

CMN 5

24 V

TRANSFORMER

115 VAC

BYPASS SWITCH

DOOR

CONTROL (A)

DOOR

CONTROL (B)

INPUT DOOR B
PUSH BUTTON
2-6 2-7

INPUT DOOR A
PUSH BUTTON
2-1 2-2

DOOR (B)

OUTPUT

1-6 1-7

DOOR (A)

OUTPUT

1-3 1-4

24VAC

ISO RELAY

COIL

24VAC

ISO RELAY

COIL

6 CMN

5 CMN

01

NOTES: 1) WIRE PUSH PLATES COMMON AND NORMALLY OPEN.
2) SYSTEM OPERATES IN THE iNTERLOCK MODE WHEN
BYPASS SWITCH IS OPEN.

80.0009

TITLE: MC-50 WITH BYPASS SWITCH
(NORMALLY BYPASSED)

(A) PUSH

PLATE

(B) PUSH

PLATE

8

7

8

7

4 N/O
2 N/C

3 N/O

1 N/C

N/C 1

N/O 3

N/C 2

N/O 4

MC-50

We open up New Horizons