suction fitting as required. When making

this connection ensure there are a

minimum of restrictions such as elbows

and couplings. Also, to protect the

pump from debris a strainer shall be

installed in the suction connection.

CAUTION: Always connect
the black wire to the negative
battery terminal last.

11. Connect the pump electrical system

to a 12 volt battery to provide power to

start the pump. Always connect the

positive battery cable first.

NOTE: The pump may be
connected to the apparatus
battery or a separate battery
may be used.

INITIAL OPERATION CHECKOUT

After activating the battery on the

portable pump, or installing the "X" series

pump, prior to placing the pump into

DISCHARGE GAUGE

TUBING CONNECTION

SUCTION GAUGE

TUBING CONNECTION

making discharge piping connection.

f. After the discharge connection is

complete tighten the "V"-band

clamp to prevent leakage.

8. Connect the exhaust priming lever

cable to the exhaust primer.

9. Connect tubing for the suction and

discharge gauges. Use the 1/4 inch

diameter tubing provided with the

pump for gauge connections. If a

longer length of tubing is required use 1/

4 inch diameter tubing rated at the

maximum operating pressure of the

pump. Connections to the gauges and

pump are compression type. Make sure

the gauge lines are connected to the

proper connection on the pump body.

10. Make piping connection to the

EXHAUST PRIMER

CABLE

CONNECTION