Compressor (cont’d)

MAINTENANCE (cont’d)

Relieve the air pressure in the system and open the petcock on the

bottom of the tank to drain.

WARNING! CONDENSATION WILL ACCUMULATE IN THE TANK. TO

PREVENT CORROSION OF THE TANK FROM THE INSIDE, THIS MOISTURE

MUST BE DRAINED AT THE END OF EVERY WORKDAY. BE SURE TO WEAR

PROTECTIVE EYEWEAR.

Note: In cold climates, drain the tank after each use to reduce problems with

freezing of water condensation.

Testing for Leaks

Check that all connections are right. A small leak in any of the hoses or pipe

connections will substantially reduce the performance of your air compressor. If you

suspect a leak, spray a small amount of soapy water with spray bottle. If bubbles

appear, repair or replace the faulty component. Do not over tighten any connections.

Storage

Before storing the compressor for a prolonged period, use an air blow gun to clean all

dust and debris from the STORAGE compressor. Disconnect the power cord and coil

it up. Pull the pressure relief valve to release all pressure from the tank. Cover the

entire unit to protect it from moisture and dust.

Servicing

Perform the following maintenance at the intervals indicated below:

• Operate the pressure relief valve: Daily

• Drain air from tank daily