Radiant heater specifications, Model – L.B. White I-34 Infraconic Pilot Ignition User Manual

Page 4

Advertising
background image

POULTRY

SWINE

"B"

"A"

"C"

I

34

Maximum Input (Btuh)

34,200

Ventilation Air to Support Combustion

400 CFM

Zone Control

PROPANE VAPOR OR

Full Output Pressure

NATURAL GAS

Zone Control, Pilot System

PROPANE VAPOR OR

Pilot Pressure

NATURAL GAS
“A”

26 3/8 in.

“B”

20 1/4 in.

“C”

10 3/8 in.

Net Weight

12 lbs 7 oz.

PROPANE GAS

1.58 lbs./hr.

NATURAL GAS

CHICKENS

2500-3800

TURKEYS

800-950

SWINE

300

CHICKENS

6-7 ft.

TURKEYS

4.5 ft.

SWINE

4-5 ft.

TOP OF HOOD TO CEILING

3 ft.

POINT OF COMBUSTION
CONE TO FLOOR

SIDES

3 ft.

VERTICAL FROM FLOOR

6-12 in.

HORIZONTAL FROM BROODER

8-12 ft.

VERTICAL FROM FLOOR

Above Animal Height

HORIZONTAL FROM BROODER

4-8 ft.

4

SPECIFICATIONS

Model

Radiant Heater Specifications

FIG. 1

Heater Dimensions
(See Fig. 1)

Fuel Consumption Per Hour

Animal Coverage Per Heater (1)

Minimum Safe Clearances to
Combustible Materials

Recommended Height Installation
For Livestock From Point of
Combustion Cone to Floor

4.5 ft.

34.2 CFH

20 - 22 in. W.C.

5 PSIG

(1)

There are other factors that will affect the quantity of animals each heater can cover. These include building ventilation and control
systems, building insulation, building size and population density, etc. Consult your L. B. White dealer or call L. B. White for specific
recommendations for your application.

(2)

This is a typical sensor height range for poultry installations. The size and type of livestock being grown, heater spacing and height,
etc. will dictate sensor height. Care should always be taken to ensure that the sensor is sufficiently high as to not be damaged by
the animal during operation.

Animal Occupied Zone Temperature
Control Sensor Location (2)

Advertising