REMOVING MOTOR FROM BASE

To remove motor from non-plunge bases:
(Fig. 6)
1. Hold router in horizontal position, open

base clamp lever, depress coarse
adjustment lever, and pull motor upwards
until it stops.

2. Turn motor counter-clockwise, and gently

pull it free of base.

To remove motor from plunge base: (Fig. 7)
1. Hold router in horizontal position, open

base clamp lever, and pull motor upwards
until it stops.

2. Turn motor counter-clockwise, and gently

pull it free of base.

INSTALLING MOTOR IN BASE

The motor can be installed with the switch
positioned on the right or left of the base from
the operator's side (and the cord facing the
opposite side of the router). Install the motor
so that the switch is in the location you find to
be the most easily accessible from the
handles. The switch should be easier to turn
"OFF" than "ON" in case of an emergency.
To install motor in non-plunge base:
1. Release the base clamp lever.

2. Line up the arrow on the base with arrow

on the motor. (Fig. 8)

• To position switch on the right side of the

base, line up the base’s arrow with
motor housing’s arrow that is below the
cord.

• To position switch on the left, line up the

base’s arrow with motor housing’s arrow
that is below the switch.

3. While pressing the coarse adjustment

lever, slide motor into base until resistance
in felt. (The base’s guide pin is now
engaged into slot on motor.)

4. Continue to press coarse adjustment lever,

and turn the motor clockwise until it stops.

5. Push the motor into the base until it

reaches the approximate desired depth.

6. Release the coarse adjustment lever and

slide the motor forward or back as needed
until the coarse adjustment system’s
“catch” springs into the coarse adjustment
detent notch.

7. Set final height position as described

below in “Operating Instructions”.

To install motor in plunge base:
1. Release the base clamp lever.

2. Line up the arrow on the base with arrow

on the motor. (Fig. 8)

• To position switch on the right side of the

base, line up the base’s arrow with
arrow on the motor housing that is
below the cord.

-9-

ALIGNMENT

ARROWS

COARSE

ADJUSTMENT

NOTCHES

MOTOR

BASE

FIG. 8

BASE

CLAMP

LEVER

FIG. 6

COARSE

ADJUSTMENT

LEVER

BASE

CLAMP

LEVER

FIG. 7