588-OEM-250ps Board Level Connection Information

588-OEM-250ps Board Level Overview

The 588-OEM-250ps is a board level option based on the 588 series pulse generator. The

specifications, communications, and overall functionality of the OEM model are the same as

described for the Model 588. The unit is available with either 4 or 8 independent outputs

that can be used for synchronizing multiple events. The 588-OEM-250ps all communications will

take place through USB, Ethernet, or RS-232 as there is no display or keypad for

interactions. The guide for standard SCIP communications with the unit can be found

above in the 588 standard manual. As with the 588, the OEM version is capable of generating

multiple pulses for all applications; but additional setup is required before even basic

pulsing may begin.

Digital Control Board Connection Information

*Note: The Power Input and Power Switch Connector are required connections for the 8530

module to function.

Power Input Connector (J2 - DC In)

The recommended connector is Molex 4 pin female C-grid (Molex #50-57-9404) or

equivalent.

The recommended contacts are Molex female terminals with

gold contacts (Molex #16-

02-0087) or equivalent.

Pin Number:

Connection:

Specification:

1 (denoted by arrow on connector)

+5 Volts DC

5V±2%, 1.2 Amp nominal capability

2

Ground

3

Ground

4

+24 Volts DC

24V±6%, 0.8A nominal capability

*Note: For an additional cost a recommended power supply and cable can be supplied

Power Switch Connector (J4 Pwr_Enab)

The recommended connector is Molex 2 pin female C-grid (Molex #50-57-9402) or

equivalent.

The recommended contacts are Molex female terminals with

gold contacts (Molex #16-

02-0087) or equivalent.

*Note: This is the power enable switch; Short the contacts to turn the unit on and open them to

power down. (This connector will come shorted)

BNC Model 588-OEM-250ps

1