General maintenance, Air cleaner – SkyTrak 3606 Operation Manual User Manual

Page 108

Advertising
background image

106

3606 Rev 11/99

General Maintenance

The operator’s display panel illuminates an indicator light that will alert the
operator when it senses restricted air flow to the engine. This indicates the
air filter(s) need servicing. NEVER operate the vehicle without the air
cleaner assembly and both filters in place.

Figure 65

A. Element: Change or Clean

(As Restriction Indicator Indicates or
Every 500 Hour Intervals)

Outer Primary Element

All air cleaner manufacturers agree that attempting to clean or wash an
element increases the chance for element damage. It is highly
recommended that you consider the value of cleaning an element against
the risks which could lead to engine damage. Adopt the policy that all
elements should be replaced with new and not cleaned.

2. Air Cleaner

OS0440

Air Cleaner Cover

Vactuator

Valve

Air

Cleaner

Retaining

Clips

OS0790

106

3606 Rev 11/99

General Maintenance

The operator’s display panel illuminates an indicator light that will alert the
operator when it senses restricted air flow to the engine. This indicates the
air filter(s) need servicing. NEVER operate the vehicle without the air
cleaner assembly and both filters in place.

Figure 65

A. Element: Change or Clean

(As Restriction Indicator Indicates or
Every 500 Hour Intervals)

Outer Primary Element

All air cleaner manufacturers agree that attempting to clean or wash an
element increases the chance for element damage. It is highly
recommended that you consider the value of cleaning an element against
the risks which could lead to engine damage. Adopt the policy that all
elements should be replaced with new and not cleaned.

2. Air Cleaner

OS0440

Air Cleaner Cover

Vactuator

Valve

Air

Cleaner

Retaining

Clips

OS0790