6-1.

Connect the Power Supply Lead to the Raptor™, by inserting the 2 pin Deutsch
connector on the end of the wiring harness into the corresponding connector on the
Raptor™.





Figure 21


6-2.

Crimp the male spade connector onto the end of the Red (+) wire.




Ground Wire

Hot Lead

Water Resistant Fuse

Raptor™ Pump Lead


Figure 22

Figure 23

Figure 24

6-3.

To connect the positive lead, route the Red (+) wire to the fuse panel located under the

hood on the driver’s side wheel house. Insert the male spade connector into a spare fuse

holder on the fuse panel that is “hot” when the starter key is turned to the on position.

6-4.

Connect the Green (-) wire to an adequate ground.

BE SURE TO PROPERLY ROUTE AND SECURE THE WIRING HARNESS TO THE

VEHICLE.