Section 5-E High Flow Suction Tube

INSTALLING THE HIGH FLOW SUCTION TUBE, C

ont’d


5D-5. Measure and cut the suction tube to a length that will allow approximately 1/8”

clearance off the bottom of the tank. It is suggested to form the end of the tube similar
to Figure 40.

Figure 40

5D-6. Lubricate the bulkhead fitting with motor oil. Pressing firmly, insert the suction tube

assembly into the grommet. Be sure the bulkhead fitting is completely seated in the

grommet.

Figure 41

Figure 42




5D-7. Re-install the Collection basket.

Figure 43


5D-8. Connect the end of the “Suction Hose Assembly” to the bulk head fitting while it is

easily accessible. A “click” will be heard when it is properly installed.

5D-9 Any excess fuel hose can be addressed by routing the hose in a fashion to take up

the extra length, or a section of the hose can be removed. Push lock splices have

been included if you choose to remove the excess hose