INSTALLING THE SLIM LINE® INSTRUMENT SERIES

PAGE 13 OF 14

REV

B

the Kollsman window. Or use the chart below to calculate the MP FACTOR. Multiply this MP FACTOR by the
altimeter setting that you receive from ATIS or unicom. For example if the field elevation is 1700 ft and the
current altimeter setting is 30.1, the MP FACTOR is determined to be 0.9400 from the table. Multiply 30.1 x
0.9400 to obtain the ambient MP of 28.29.
Adjust the zero set pot as shown on the above diagram so that the MP reading is the same as the ambient MP
determined above.

Field Elev MP FACTOR

Field Elev MP FACTOR

Field Elev MP FACTOR

Field Elev MP FACTOR Field Elev MP FACTOR

-500 1.0182
-400 1.0145
-300 1.0109
-200 1.0073
-100 1.0036

0 1.0000

100 0.9964
200 0.9928
300 0.9892
400 0.9856
500 0.9821
600 0.9785
700 0.9750
800 0.9714
900 0.9679

1000 0.9644
1100 0.9609
1200 0.9574
1300 0.9539
1400 0.9504
1500 0.9469
1600 0.9435
1700 0.9400
1800 0.9366
1900 0.9332
2000 0.9298
2100 0.9264
2200 0.9230
2300 0.9196
2400 0.9162

2500

0.9129

2600

0.9095

2700

0.9062

2800

0.9028

2900

0.8995

3000

0.8962

3100

0.8929

3200

0.8896

3300

0.8863

3400

0.8830

3500

0.8798

3600

0.8765

3700

0.8733

3800

0.8700

3900

0.8668

4000

0.8636

4100

0.8604

4200

0.8572

4300

0.8540

4400

0.8508

4500

0.8477

4600

0.8445

4700

0.8414

4800

0.8382

4900

0.8351

5000

0.8320

5100

0.8289

5200

0.8258

5300

0.8227

5400

0.8196

5500

0.8165

5600

0.8135

5700

0.8104

5800

0.8074

5900

0.8043

6000

0.8013

6100

0.7983

6200

0.7953

6300

0.7923

6400

0.7893

6500

0.7863

6600

0.7833

6700

0.7804

27) Warranty

J. P. Instruments, Inc. (JPI), warrants all parts in your new Slim Line to be free from defects in material and
workmanship under normal use. Our obligation under this warranty is limited to repair or exchange of any
defective part of this unit if the part is returned, shipping prepaid, within two years for electronics and one year
for probes from the date of original purchase. Installation labor is the responsibility of the aircraft owner.
Homebuilt aircraft warranty starts when the aircraft is certified for flight. Replacement parts carry a warranty
for the balance of the warranty period.
Under this warranty, JPI is not responsible for any service charges, including removal, installation, nor any
other consequential damages. JPI incurs no obligation under this warranty unless a Warranty Registration
Certificate describing the warranted product has been completed and mailed to JPI with all information
requested.
This warranty is void on any product which has been subject to misuse, accident, damage caused by negligence,
damage in transit, handling or modification which, in the opinion of JPI, has altered or repaired the product in
any way that effects the reliability or detracts from the performance of the product, or any product whereon the
serial number has been altered, defaced, effaced or destroyed.
This warranty is in lieu of all other warranties expressed or implied and other obligations of liability on JPI’s
part, and it neither assumes nor authorizes any other person to assume for JPI any other liability in connection
with the sale of JPI products.
To initiate this warranty, the aircraft owner must submit a completed warranty card to JPI. JPI will initiate the
warranty from the date of original purchase. Any replacement parts carry a warranty that extends for the balance
of the period of the original warranty. For homebuilt aircraft the warranty starts when the aircraft is certificated
for flight and noted on the warranty card.

Advertising