Removing the Vacuum Chamber

1.

Pull the chamber release lever.

2.

Lift the vacuum chamber and remove it from the
appliance.

Replacing the Vacuum Chamber

1.

Slot the right end of the chamber into the
recess.

2.

Ensure the suction nozzle (A) connects securely
with the vacuum chamber, and the positioning
knob (B) sits securely in its seat.

3.

Press the left side of the chamber down until the
release lever clicks back into place.

Troubleshooting

Fault

Probable Cause

Action

The unit is not working

The unit is not switched on

Check the unit is plugged in correctly
and switched on

Plug and lead are damaged

Call BUFFALO agent or qualified
technician

Fuse in the plug has blown

Replace the plug fuse

Power supply

Check power supply

Internal wiring fault

Call BUFFALO agent or qualified
technician

Appliance does not remove all
the air from the bag

Open end of bag not
completely inserted

Open lid and reposition bag

Gaskets dirty

Clean gaskets

Open end of bag is dirty

Clean bag

Bag may be punctured

Line bag with paper towels to protect
against foodstuffs with sharp edges
Replace bag

Incorrect bags used

Call Vacuum Pack machine supplier

Bags are not sealing correctly

Sealing bar is overheating

Open lid and allow sealing bar to cool
down

Incorrect bags used

Call Vacuum Pack machine supplier

Advertising