AEM 30-3501 Infinity Plug & Play Harnesses - Honda/Acura OBD1 User Manual

Page 8

Advertising
background image

8

© 2014 AEM Performance Electronics

P/N 30-3501

Infinity

Pin

Infinity

Assignment

Honda Pin

Honda Description

Infinity Hardware

Specification

Notes

32

Digital 7

---

---

10K pullup to 12V. Will work

with ground or f loating

switches.

Input can be assigned to dif f erent pins. See
Setup Wizard page Input Function
Assignments f or input mapping options.
*Coil 8 f or Inf inity 8h.

33

GND

A23

Power Ground 1

Power Ground

Connects to chassis ground and AEMNet

34

CAN A -

---

---

Dedicated High Speed CAN

Transceiv er

4P DTM Connector f ound in AEM adapter
harness. Contact AEM f or additional
inf ormation.

35

CAN A +

---

---

Dedicated High Speed CAN

Transceiv er

4P DTM Connector f ound in AEM adapter
harness. Contact AEM f or additional
inf ormation.

36

CAN B -

---

---

Dedicated High Speed CAN

Transceiv er

Not used

37

CAN B +

---

---

Dedicated High Speed CAN

Transceiv er

Not used

38

Temp 1 -

Coolant Temp

D13

Engine Coolant Temp

Sensor

12 bit A/D, 2.49K pullup to

5V

See "Coolant Temperature" Setup Wizard f or
selection.

39

Temp 2 - Air

Temp

(Manif old)

D15

Intake Air Temp

Sensor

12 bit A/D, 2.49K pullup to

5V

See "Air Temperature" Setup Wizard f or
selection.

40

Temp 3 - Oil

Temp

---

---

12 bit A/D, 2.49K pullup to

5V

Found on the Aux Connector. 0–5V analog
signal.

41

LS 0

A7

Fuel Pump Relay

Lowside switch, 4A max, No

internal f ly back diode.

Switched ground. Will prime f or 2 seconds at
key on and activ ate if RPM > 0.

42

LS 1

---

---

Lowside switch, 4A max with

internal f ly back diode.

Inductiv e load should NOT

hav e f ull time power.

Found in Aux Connector. See Setup Wizard
page Boost Control f or options. Monitor
BoostControl [%] channel f or output state.

43

GND

A24

Power Ground 2

Power Ground

Connect directly to battery ground.

44

Knock 0

D3

Knock Sensor

Dedicated knock signal

processor

See Knock in Setup Wizard f or options.

45

Knock 1

---

Dedicated knock signal

processor

See Knock in Setup Wizard f or options.

46

GND

---

Power Ground

Connect directly to battery ground.

47

12V_Relay _C

ontrol

---

---

0.7A max ground sink f or

external relay control

Connects to relay f ound in AEM adapter. Will
activ ate at key ON and at key OFF
according to the conf iguration settings.

48

+12V SW (Ign

Switch)

B1

Power Source 1

10K pulldown

Full time battery power must be av ailable at
inf inity pin 10 bef ore this input is triggered.

49

+5V_Out

D19

Sensor Voltage 1

Regulated, f used +5V

supply f or sensor power

Analog sensor power and f ound on auxiliary
connector

50

+5V_Out

D20

Sensor Voltage 2

Regulated, f used +5V

supply f or sensor power

Analog sensor power

51

Ana7 - Throttle

D11

Throttle Position

Sensor

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Do not connect signals
ref erenced to +12V as this can permanently
damage the ECU. See the Setup Wizard Set
Throttle Range page f or automatic min/max
calibration.

52

Ana8 - Map

D17

MAP Sensor

12 bit A/D, 100K pullup to 5V

0–5V analog signal. See the Manif old
Pressure in Setup Wizard f or setup and
calibration.

Advertising