AEM 30-3501 Infinity Plug & Play Harnesses - Honda/Acura OBD1 User Manual
Page 8
8
© 2014 AEM Performance Electronics
P/N 30-3501
Infinity
Pin
Infinity
Assignment
Honda Pin
Honda Description
Infinity Hardware
Specification
Notes
32
Digital 7
---
---
10K pullup to 12V. Will work
with ground or f loating
switches.
Input can be assigned to dif f erent pins. See
Setup Wizard page Input Function
Assignments f or input mapping options.
*Coil 8 f or Inf inity 8h.
33
GND
A23
Power Ground 1
Power Ground
Connects to chassis ground and AEMNet
34
CAN A -
---
---
Dedicated High Speed CAN
Transceiv er
4P DTM Connector f ound in AEM adapter
harness. Contact AEM f or additional
inf ormation.
35
CAN A +
---
---
Dedicated High Speed CAN
Transceiv er
4P DTM Connector f ound in AEM adapter
harness. Contact AEM f or additional
inf ormation.
36
CAN B -
---
---
Dedicated High Speed CAN
Transceiv er
Not used
37
CAN B +
---
---
Dedicated High Speed CAN
Transceiv er
Not used
38
Temp 1 -
Coolant Temp
D13
Engine Coolant Temp
Sensor
12 bit A/D, 2.49K pullup to
5V
See "Coolant Temperature" Setup Wizard f or
selection.
39
Temp 2 - Air
Temp
(Manif old)
D15
Intake Air Temp
Sensor
12 bit A/D, 2.49K pullup to
5V
See "Air Temperature" Setup Wizard f or
selection.
40
Temp 3 - Oil
Temp
---
---
12 bit A/D, 2.49K pullup to
5V
Found on the Aux Connector. 0–5V analog
signal.
41
LS 0
A7
Fuel Pump Relay
Lowside switch, 4A max, No
internal f ly back diode.
Switched ground. Will prime f or 2 seconds at
key on and activ ate if RPM > 0.
42
LS 1
---
---
Lowside switch, 4A max with
internal f ly back diode.
Inductiv e load should NOT
hav e f ull time power.
Found in Aux Connector. See Setup Wizard
page Boost Control f or options. Monitor
BoostControl [%] channel f or output state.
43
GND
A24
Power Ground 2
Power Ground
Connect directly to battery ground.
44
Knock 0
D3
Knock Sensor
Dedicated knock signal
processor
See Knock in Setup Wizard f or options.
45
Knock 1
---
Dedicated knock signal
processor
See Knock in Setup Wizard f or options.
46
GND
---
Power Ground
Connect directly to battery ground.
47
12V_Relay _C
ontrol
---
---
0.7A max ground sink f or
external relay control
Connects to relay f ound in AEM adapter. Will
activ ate at key ON and at key OFF
according to the conf iguration settings.
48
+12V SW (Ign
Switch)
B1
Power Source 1
10K pulldown
Full time battery power must be av ailable at
inf inity pin 10 bef ore this input is triggered.
49
+5V_Out
D19
Sensor Voltage 1
Regulated, f used +5V
supply f or sensor power
Analog sensor power and f ound on auxiliary
connector
50
+5V_Out
D20
Sensor Voltage 2
Regulated, f used +5V
supply f or sensor power
Analog sensor power
51
Ana7 - Throttle
D11
Throttle Position
Sensor
12 bit A/D, 100K pullup to 5V
0–5V analog signal. Do not connect signals
ref erenced to +12V as this can permanently
damage the ECU. See the Setup Wizard Set
Throttle Range page f or automatic min/max
calibration.
52
Ana8 - Map
D17
MAP Sensor
12 bit A/D, 100K pullup to 5V
0–5V analog signal. See the Manif old
Pressure in Setup Wizard f or setup and
calibration.