Pinouts, Infinity pinout – AEM 30-3502 Infinity Plug & Play Harnesses - Honda/Acura K-Series Engine User Manual

Page 6

Advertising
background image

6

© 2014 AEM Performance Electronics

P/N 30-3502

PINOUTS

Infinity Pinout

Dedicated

Dedicated and not reconfigurable

Assigned

Assigned but reconfigurable

Available

Available for user setup

Not Applicable

Not used in this configuration

Required

Required for proper function

Infinity

Pin

Infinity

Assignment

Honda

Pin

Honda Description

Infinity Hardware

Specification

Notes

1

LS 4

E26

Engine Speed Pulse

Lowside switch, 4A max, No

internal f ly back diode.

The tachometer is pre-calibrated using a
combination of the LS4_Freq [Hz] 1-axis table
and the LS4_Duty [%] 2-axis table.

2

LS 5

B23

Variable Valv e Timing

Control

Lowside switch, 4A max with

internal f ly back diode.

Inductiv e load should NOT

hav e f ull time power.

The Variable Valv e Timing Control is pre-
calibrated using a combination of the LS5_Freq
[Hz] 1-axis table and the LS5_Duty [%] 2-axis
table.

3

LS 6

C5

---

Lowside switch, 4A max with

internal f ly back diode.

Inductiv e load should NOT

hav e f ull time power.

See Wizard page "LowSide Assignment Tables"
f or output assignment.
*Spare injector output Injector 7 f or Inf inity 8h.

4

LS 7

C4

---

Lowside switch, 4A max, No

internal f ly back diode.

See Wizard page "LowSide Assignment Tables"
f or output assignment.
*Spare injector output Injector 8 f or Inf inity 8h.

5

UEGO1

Heat

---

---

Bosch UEGO controller

Lowside switch f or UEGO heater control.
Connect to pin 4 of Bosch UEGO sensor. NOTE
that pin 3 of the Sensor is heater (+) and must be
power by a f used/switched 12V supply .

6

UEGO1 IA

---

---

Bosch UEGO controller

Trim Current signal. Connect to pin 2 of Bosch
UEGO sensor.

7

UEGO1 IP

---

---

Bosch UEGO controller

Pumping Current signal. Connect to pin 6 of
Bosch UEGO sensor.

8

UEGO1 UN

---

---

Bosch UEGO controller

Nernst Voltage signal. Connect to pin 1 of Bosch
UEGO sensor.

9

UEGO1 VM

---

---

Bosch UEGO controller

Virtual Ground signal. Connect to pin 5 of Bosch
UEGO sensor.

10

+12V Perm

Power

---

Voltage Back Up

Dedicated power management

CPU

Full time battery power. MUST be powered bef ore
the ignition switch input is triggered. NOTE: Fused
battery power need to supply to the f ly ing lead on
the AEM adapter harness.

11

Coil 4

A27

Ignition Coil Pulse

No. 4

25 mA max source current

0–5V f alling edge f ire. Do NOT connect directly
to coil primary . Must use an ignitor or CDI that
accepts a f alling edge f ire signal.

12

Coil 3

A28

Ignition Coil Pulse

No. 3

25 mA max source current

0–5V f alling edge f ire. Do NOT connect directly
to coil primary . Must use an ignitor or CDI that
accepts a f alling edge f ire signal.

13

Coil 2

A29

Ignition Coil Pulse

No. 2

25 mA max source current

0–5V f alling edge f ire. Do NOT connect directly
to coil primary . Must use an ignitor or CDI that
accepts a f alling edge f ire signal.

Advertising