AEM 30-5131M Analog EGT Metric Gauge User Manual

Page 6

Advertising
background image

Page 6

VOLTAGE

°F

°C

0.50

0

-18

0.75

113

45

1.00

225

107

1.25

338

170

1.50

450

232

1.75

563

295

2.00

675

357

2.25

788

420

2.50

900

482

2.75

1013

545

3.00

1125

607

3.25

1238

670

3.50

1350

732

3.75

1463

795

4.00

1575

857

4.25

1688

920

4.50

1800

982




Connector Pinouts

The pinouts for the 3-pin sensor harness and 8 pin power harness are provided

below in Figure 6.




Specifications

Gauge
Supply Current

<0.100 A

Differential Analog Outputs

1

Measuring Range

0

– 1800 Degrees Fahrenheit,

-18-982 Degrees Celsius

Sensor Accuracy

0.75% FS

Operating Voltage (nominal)

8.5-15 volts dc

Harness & Connector Temp Limit: 105C





Figure 6. Harness Pinouts