Status Light

Fault

Corrective Action

Left

Sensor Wiring and/or sensor

Make sure sensor is

connected, check for

broken wires

Right

Sensor and/or sensor wiring

Check for shorted

sensor wires



Analog Output

The analog output from the AEM Analog boost gauge is a linear dc voltage signal that
varies from 0.5 Vdc at 30 inHg (-1 Bar) vacuum to 4.5 Vdc at 35 psi (2.4 Bar) boost
over the operating range of the gauge. The signal is used for sending information to a
data logger or an engine management system like the AEM EMS or F/IC. Since the
gauge displays different units for vacuum and boost, two different transfer functions are
needed. The vacuum (inhg) and boost (psi) transfer functions are listed below

Boost Range: 0-35 psi, 1.68 – 4.5 volts

Boost = 12.41 x Voltage – 20.85

Vacuum Range: 0-30 inhg, 0.5 – 1.67 volts

Vacuum = -25.42 x Voltage + 42.71

The transfer function for pressure units in bar is listed below. Since both the vacuum
and boost ranges use the same units, bar, a single transfer function can be used.

Vacuum/Boost Range: -1 Bar Vacuum to 2.4 Bar Boost, 0.5 – 4.5 volts

Vacuum/Boost = 0.85 x Voltage – 1.43

A list of output voltages and corresponding pressures is shown below in Table 1.