# of Flashes

Fault

Corrective Action

1-6

Sensor Wiring and/or sensor

Check sensor cable for

broken wires/shorts

7

System voltage below 10 volts dc

Check electrical system

for good connections

and proper function


Analog Output

The analog output from the AEM E85 Analog Wideband Air/Fuel Ratio gauge is a linear
dc voltage signal that varies from 0.5 Vdc at 5.6:1 AFR E85 to 4.5Vdc at 11.9:1 AFR
E85
over the operating range of the gauge. The signal is used for sending information
to a data logger or an engine management system like the AEM EMS or F/IC. The
transfer function for the output is listed below.

AFR = 1.567(V) + 4.825

For example, if the output is 2.0 Vdc, the AFR is 7.96:1
1.567 * 2.0 + 4.825 = 7.96:1

Configuring the AEM EMS

With an EMS calibration open, go to Setup>Sensors>Oxygen Sensor #1(2)>O2 Sensor
#1(2) Cal Table>Table, and enter the values below into the O2 Sensor #1(2) Cal Table.


Voltage AFR

Voltage AFR

Voltage AFR

Voltage AFR

0.00

5.6

1.40

7.0

2.81

9.2

4.21

11.4

0.16

5.6

1.56

7.3

2.96

9.5

4.37

11.7

0.31

5.6

1.72

7.5

3.12

9.7

4.52

11.9

0.47

5.6

1.87

7.8

3.28

10.0

4.68

11.9

0.62

5.8

2.03

8.0

3.43

10.2

4.84

11.9

0.78

6.0

2.18

8.2

3.59

10.5

4.99

11.9

0.94

6.3

2.34

8.5

3.74

10.7

NA

NA

1.09

6.5

2.50

8.7

3.90

10.9

NA

NA

1.25

6.8

2.65

9.0

4.06

11.2

NA

NA






Connect the WHITE Analog Output + wire to the EMS Lambda input and the BROWN
Analog Output

– wire to the EMS sensor ground. Table 3 below lists the Lambda and

Sensor ground pin locations for the different EMS part numbers.


Table 1. Error Codes

Table 2. EMS Software Values

Advertising