Install mounting bracket – Best WC26E User Manual

Page 10

Advertising
background image

- 10 -

INSTALL MOUNTING
BRACKET

1. Construct wood wall framing that is flush

with interior surface of wall studs. Fig. 9.
Make sure:

a) the framing is centered over

installation location.

b) the height of the framing will allow the

mounting bracket to be secured to

the framing within the dimensions

shown.

2. After wall surface is finished, secure the

mounting bracket to framing with (2) 4.8 x

38mm mounting screws. See chart below

for mounting bracket location.

Notes:

a. Minimum hood distance above cook top must not be less than 22”.

A maximun of 28” above cook top is highly recommended for best capture of

cooking impurities.

Distances over 28” are at the installer and user’s discretion; and if ceiling height

and flue length permits.

b. Requires optional 10’ flue extension, ducted model AEWC26xB.

HOOD DISTANCE ABOVE 36” HIGH COOK TOP (see note a)

28”

MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP

47-1/4”

CEILING HEIGHT

8-FOOT

9-FOOT

22”

23”

24”

25”

26”

27”

41-1/4”

42-1/4”

43-1/4”

44-1/4”

10- FOOT (see note b)

45-1/4”

46-1/4”

41-1/4”

42-1/4”

43-1/4”

44-1/4”

41-1/4”

42-1/4”

43-1/4”

44-1/4”

47-1/4”

45-1/4”

46-1/4”

FRAMING BEHIND

WOOD CROSS

SUPPORT

WOOD CROSS

SUPPORT BEHIND

DRYWALL

DRYWALL

FIG. 9

Advertising