Service & maintenance instructions, User manual – Bertazzoni X304GGVX User Manual

Page 12

Advertising
background image

12

WARNING: The above-mentioned adjustment should be made only for natural gas, while for operation with

liquid gas the screw must be locked at the end in a clockwise direction. The broiler burner always
operates at maximum and therefore no minimum adjustment is required.

SERVICE & MAINTENANCE INSTRUCTIONS

Service and maintenance only to be carried out by an authorised person
To replace parts such as burners, valves and electric components, the appliance must be open removing the worktop.

Note: if the valves must be replaced, first disassemble the ignitions switches wires.

It is recommended to replace the valve gaskets each time the valve is replaced, thus ensuring a perfect seal between the
body and the gas train.

WARNING: After first installation of the appliance or after any service intervention concerning main gas parts of
the appliance, make the leak test using water with soap on the gas connections in order to verify the correct
installation. Do not use fire for gas leak testing.

To replace the oven bulb, just unscrew the protection cap that projects out inside the oven. (Fig.19) WARNING:
Disconnect power before servicing unit.

In order to remove the oven door make sure to block the ihinges with a screw driver.

Call an autorised service person for this operation that can be dangerous

USER MANUAL

WARNINGS:
Keeping appliance area clear and free from combustible materials, gasoline and other flammable
vapors and liquid.
Do not store dangerous or flammable material in the cabinet areas above appliance; store them in a
safe place in order to avoid potential hazards.

Do not use aerosol sprays in the vicinity of this appliance while it is in operation
Do not use oven doors as support or for sit-down.
Do not use oven cavity as storage compartment.

Advertising
This manual is related to the following products: