Freezer w/self-contained condenser, Shipping information, Other technical information – Blodgett 30084SB User Manual

Page 2: Technical information

Advertising
background image

BLODGETT

www.blodgett.com

1100 Old Honeycutt Road Fuquay-Varina, NC 27526 USA • Phone: (877) 255-3976 • Fax: (866) 644-1354

Printed in U.S.A.

NOTE: FOR COMMERCIAL USE ONLY

APPROVAL/STAMP

P/N BR00040 Rev A (1/08)

FREEZER W/SELF-CONTAINED

CONDENSER

SHORT FORM SPECIFICATIONS
The item shall be freezer base-section for a sectional range. Unit shall a have 430 stainless steel #3 polish top, front, sides, back, drawers and interior cavity. The item shall have draw-
ers that hold standard sized (12” x 20” x 4”) pans (not included). The drawer assemblies shall be removable for cleaning. The unit shall include a 6’ (152cm) power cord with grounded
plug to receive 50 or 60hz, single phase, 120VAC electric power. The unit shall have a self contained condenser. The unit shall be at most 32-1/2” deep and shall be 26” high including
adjustable 6” legs. Refrigerant is CFC-free R-404a. Provide options and accessories as indicated.

NOTE: The company reserves the right to make substitutions of components without prior notice

DIMENSIONS ARE IN INCHES (MM).

Model 30084SB

84 (2134)

Model 30036SB

36 (914)

Model 30060SB

60 (1524)

96 (2438)

Model 30096SB

Model 30108SB

108 (2743)

Model 30072SB

72 (1829)

Model 30048SB

48 (1219)

Model 30120SB

120 (3048)

32-1/2 (826)*

Power

Cord

26

(660)

6 (152)

Condensate

Drain Tube

RIGHT SIDE

REAR VIEW

Minimum clearance on all sides is 3” (76mm). However, modular
range-top sections can be mounted directly on top using an
insulated base adapter. Also, these refrigerated bases can be
part of a sectional battery provided that the adjoining base
sections are insulated (or do not produce heat).

SHIPPING INFORMATION

Approximate weight:
30036SB

340 lbs (154 kg)

30048SB

410 lbs (186 kg)

30060SB

550 lbs (249 kg)

30072SB

650 lbs (295 kg)

30084SB

745 lbs (338 kg)

30096SB

855 lbs (388 kg)

30108SB

960 lbs (435 kg)

30120SB

1075 lbs (488 kg)

OTHER TECHNICAL INFORMATION

Avoid locating where the temperature will drop below 55

°

F

(13

°

C) or rise above 90

°

F (32

°

C).

Check local codes for fire and sanitary regulations.

Model

Width

Cooled Volume

ft

3

(m

3

)

Cooling Capacity

BTU/hr

Electricity

120V amps

Recommended

Compressor

30036SB

36”

4 (0.11)

1450

8

1/3 H.P.

30048SB

48”

6.7 (0.19)

1670

8

1/3 H.P.

30060SB

60”

10 (0.28)

1802

8

1/3 H.P.

30072SB

72”

13 (0.37)

1875

10.1

1/2 H.P.

30084SB

84”

16 (0.45)

1920

10.1

1/2 H.P.

30096SB

96”

18 (0.51)

1955

20

3/4 H.P.

30108SB

108”

22 (0.62)

1955

20

3/4 H.P.

30120SB

120”

25.5 (0.72)

2000

20

3/4 H.P.

TECHNICAL INFORMATION