Transferring data from the scs2 to the key, Updating the date and time in the scs2, Replacing batteries – MBW SCS2 User Manual

Page 9

Advertising
background image

- 7 -

4.

The amount of memory being used is displayed
according to Table 2.

Transferring Data From the SCS2 to the Key

1.

Turn the SCS2 power off.

2.

Insert a data key into the SCS2.

3.

Turn on the SCS2.

4.

The SCS2 will perform the self-test, check to see if
there is room on the key for the data, and then
immediately transfer the data in the SCS2 to the key.

Note: The MEMORY light will flash while the data is

transferring to the key. If the key contains data, the
new records will be appended after the original
records on the key.

5.

When the data transfer is complete, the READY light
will come on to signal the SCS2 is ready to monitor
compaction.

Updating the Date and Time in the SCS2

The procedure for updating the date and time requires a
blank data key and a data key reader. The procedure is
outlined in “Updating Date and Time In the Meter” on page
12.

Replacing Batteries

1.

Slide the battery cover (located on the back of the
SCS2) in the direction of the “open” arrow. Lift the
cover off.

2.

Remove old batteries and dispose of properly.

3.

Insert four new batteries making sure the positive
side is on the same side as indicated by the positive
sign in the batter compartment.

4.

Put the battery cover back on the SCS2.

CAUTION

Failure to install batteries in the correct orienta-
tion may result in damage to the unit.

CAUTION

Replace all batteries at the same time. Do not mix
old and new batteries.

Lights

Memory Used

g

On*

0-30% 31-60% 61-94%

95+%

Stop

x

Indicator 2

x

x

Indicator 1

x

x

x

Processing

x

x

x

x

*In addition to MEMORY FULL light.

Table 2 - Memory Indicator Lights

Advertising