Sensor maintenance, Sensor relay/alarm testing – MBW V.E.U. User Manual

Page 10

Advertising
background image

- 7 -

3.

Slide filter out of housing.

4.

Remove prefilter and wash with clean warm water.

5.

Wash filter with low pressure water, Such as from a
garden hose. DO NOT use a high pressure sprayer.
If any holes or thin spots are apparent in filter, It must
be replaced.

6.

Let filters air dry.

7.

Put prefilter around filter, and slide into canister
housing. The rear of the filter is supported by a tab
welded to the back wall of canister.

8.

Install front cover making sure filter is straight and
seated against rear wall and cover. Tighten knob
snugly against cover.

9.

Install front cover and knob.

Sensor Maintenance

Sensor must be calibrated before first use. Sensor is NOT
calibrated at the factory due potential errors caused by
altitude change.

Sensor programming mode is password protected. To enter
programming mode, remove cover of sensor and enter
“Mode, Mode, Up, Down, Up, Enter.” For non-intrusive
operation, see sensor manual. See Sensor manual for
further instructions.

The sensor is a sensitive piece of electronic equipment and
should be treated as such. DO NOT expose the sensor to
vibration. DO NOT expose to temperatures below -4° F or
above 122° F.

Sensor Relay/Alarm Testing

1.

Plug Electronics stand into VEU.

2.

Start engine after sensor warm-up is complete. Refer
to Starting Engine, page 5.

3.

Press test button on control panel. Engine should
shut down within seconds. Alarm and all lights
should activate. If it does not, Do Not use the VEU
until it is fixed.