Pre-Operation Safety Inspection

P

RE

-O

PERATION

S

AFETY

I

NSPECTION

NOTE: Carefully read, understand and follow all safety rules, operating instructions, labels and National Safety

Instructions/Requirements. Perform the following steps each day before use.

1. Open modules and inspect for damage, fluid leaks or missing parts.

Figure 3:

Hydraulic Tank

2. Check the level of the hydraulic fluid with

the platform fully lowered. The hydraulic
reservoir is located in the Control Mod-
ule Door. The fluid level must be
between the MIN and MAX lines. Add
hydraulic fluid if necessary.

3. Check that fluid level in the batteries is

correct.

4. Verify that batteries are charged.

5. Check that A.C. extension cord has

been disconnected from the plug in the
rear of the machine.

6. Check that all guardrails are in place

and all fasteners are properly tightened.

7. Inspect the machine thoroughly for

cracked welds and structural damage,
loose or missing hardware, hydraulic
leaks, damaged control cable, loose wire connections and wheel bolts.