2. Safety Devices

Safety Device Information

For emer gency op er a tion con trols and pro ce dures
see the Emer gency Op er a tion chap ter 9, in this
manual.

The de vices listed in this chap ter are safety de -
vices.

They are on an

RT to in crease safety in the work

place for both the op er a tor and other peo ple near
the ma chine.

Do not by-pass, disable, modify, or ignore
any of these devices. Check them carefully
at the start of each work shift to see that they
are in working order (see Daily Inspection &
Maintenance chapter 7
). If any is found to be
defective, remove the

RT from service

immediately until a qualified service
technician can make repairs.

Emergency Stop Switches

At platform control box

Figure 2.1 - Platform Control Box Emergency

Stop Switch

Press the large red EMERGENCY STOP but ton in
and the en tire ma chine stops, the en gine turns off,
and noth ing moves. This switch must be out (on) to
con trol the

RT from the plat form (pull the switch

and it will pop out).

At ground control box

Figure 2.2 - Ground Control Box Emergency

Stop Switch

Press the red EMERGENCY STOP switch cover
down, at any time, un der any con di tions, and the
en

tire ma

chine stops, the en gine turns off, and

noth ing moves. the EMERGENCY STOP switch
must be up for any thing on the

RT to work.

Alarms

There are two alarms on an

RT. One is lo cated in

the plat form con trol box, the other is lo cated in the
ground con trol box.

The alarms are con nected in par al lel, they both
emit the same pat tern of sound at the same time.
The dif fer ent alarm sound pat terns are shown in
the ta ble im me di ately be low and dis cussed be low
the table.

Figure 2.3 - Alarm Sound Patterns

The high-tem per a ture, low oil-pres sure, and al ter -
na tor not-charg ing alarms are each a con tin u ous
tone.

SR3370 & SR2770 – 13184A