Caution, Chapter 10 – emergency operation – Snorkel AB60J CE User Manual

Page 51

Advertising
background image

AB60J – 0182099EE

47

If the main hydraulic system fails, the aerial platform

may be lowered and stowed using the emergency power

system. The main boom may be lowered using the emer-

gency lowering knob. The machine may be towed if the

drive system fails. Refer to Emergency Power System,

Emergency Lowering, or Towing for the appropriate pro-

cedure.

Emergency Power System

The emergency power system can be used to operate

the machine from the lower or upper controls.

A

Caution

The emergency power system is for emergency low-

ering and stowing only. The length of time the pump

can be operated depends on the capacity of the bat-

tery. Do not use this system for normal operation.

Only use the emergency power system if the main power

system fails.

Lower Controls

Use the following procedure to operate the machine us-

ing the emergency power system from the lower con-

trols.

1. Place the battery disconnect switch in the on posi-

tion (refer to Figure 10.1).

Figure 10.1 – Battery Disconnect Switch

2. Place the key in the control selector switch (refer to

Figure 10.2) and turn the control switch to the lower

control position.

3. Pull the emergency stop button outward.

4. Hold the ground operation switch in the on position

while holding the engine/emergency power switch

down in the emergency power position.

Figure 10.2 – Lower Controls

5. Hold the appropriate function toggle switch in the

desired direction.

Upper Controls

For the upper controls to be operational:

• the battery disconnect switch must be in the on po-

sition.

• the emergency stop button at the lower controls must

be in the on position.

• the controls selector switch at the lower controls

must be in the upper controls position.

Use the following procedure to operate the machine us-

ing the emergency power system from the upper con-

trols.

1. Pull the emergency stop button outward (refer to

Figure 10.3).

2. Turn the start switch on.

3. Place the drive/boom selector switch in the appro-

priate position.

4. Step down on the platform foot switch (refer to Fig-

ure 10.4).

Chapter 10 – Emergency Operation

Battery Disconnect Switch

Ground Operation

Switch

Emergency

Stop Button

Control Selector

Switch

Engine/Emergency

Power Switch