Chapter 8 – Operation

52

AB80J/AB85J – 0420453EE

Figure 8.10 – Lower Controls

The system will remain in error mode until the excess

load is removed from the platform and the emergency

stop button or start switch is cycled off and back on,

resetting the system. At that time, the machine functions

are operational.

A

Danger

The aerial platform can tip over if it becomes unstable.

Death or serious injury will result from a tip-over ac-

cident. Do not exceed the capacity values indicated

on the platform rating placard.

The overload sensing system is not active when the ma-

chine is being driven with the main boom below horizontal

and fully retracted. This allows the machine to be driven

without the system sensing an overload due to rough

ground conditions.

To eliminate repeated tripping of the system during ma-

chine operation, there is a five second delay in machine

functions following:

starting the engine.

placing the drive/boom selector switch in the

boom position when the main boom is below

horizontal and fully retracted.

removing excess load from the platform.

AC Generator

The generator supplies power to the electrical outlet only

when the engine is running and the machine is stationary.

The machine functions will not operate when the machine/

generator selector switch is in the generator position.

A

Caution

Cold hydraulic oil does not flow well and may produce

improper generator output voltage. Improper outlet

voltage can damage some electrical power tools and

equipment. Warm the hydraulic oil before operating

the generator.

Do not operate the generator unless the hydraulic oil tem-

perature is at least 38°C (00°F). Refer to Cold Weather

Start-Up for a hydraulic oil warm-up procedure.

Start the engine and place the machine/generator switch

(refer to Figure 8.) in the generator position.

Figure 8.11 – Upper Control Panel Front

The engine will run at high idle while the generator is

operating. The generator will continue to operate as long

as the engine is running and the switch is in the genera-

tor position.

Air Line

The optional air line may be used to conduct air for tool

operation at the platform. The input connector is at the

rear of the chassis and the output connector is at the

platform on the rotator guard. The maximum working

pressure of the line is ,723 kPa (250 psi).

The air line may be used to conduct fluids such as water

or antifreeze. Contact Snorkel for compatibility information

before using the air line to conduct other fluids.

A

Caution

Fluid in the air line can damage some air tools or

freeze and damage the line. Drain and blow out the

air line after using it to conduct fluids.

Machine/Generator Switch

Platform

Overload Light

Advertising