Chapter 10 – emergency operation, Caution – Snorkel TB47J User Manual

Page 55

Advertising
background image

TB47J – 0075182

51

Figure 10.2 – Lower Controls

6. Hold the appropriate function toggle switch in the

desired direction.

Upper Controls

For the upper controls to be operational:

• the battery disconnect switch must be in the on po-

sition.

• the start switch at the lower controls must be turned

on.

• the emergency stop button at the lower controls must

be in the on position.

• the controls selector switch at the lower controls must

be in the platform position.

Use the following procedure to operate the machine us-

ing the emergency power system from the upper con-

trols.

1. Pull the emergency stop button out (refer to Figure

10.3).

2. Turn the start switch on.

Chapter 10 – Emergency Operation

If the main hydraulic system fails, the aerial platform may

be lowered and stowed using the emergency power sys-

tem. The main boom may be lowered using the emer-

gency lowering knob. The machine may be towed if the

drive system fails. Refer to Emergency Power System,

Emergency Lowering, or Towing for the appropriate pro-

cedure.

Emergency Power System

The emergency power system can be used to operate

the machine from the lower or upper controls.

A

Caution

The emergency power system is for emergency low-

ering and stowing only. The length of time the pump

can be operated depends on the capacity of the

battery. Do not use this system for normal opera-

tion.

Only use the emergency power system if the main power

system fails.

Lower Controls

Use the following procedure to operate the machine us-

ing the emergency power system from the lower con-

trols.

1. Place the battery disconnect switch in the on posi-

tion (refer to Figure 10.1).

Figure 10.1 – Battery Disconnect Switch

2. Place the key in the start switch (refer to Figure 10.2)

and turn the start switch on.

3. Place the emergency stop button in the on position.

4. Place the control selector switch in the ground posi-

tion.

5. Hold the ground controls switch in the on position

while holding the emergency power switch down in

the emergency power position.

Battery Disconnect Switch

Emergency
Stop Button

Control Selector

Switch

Ground Operation

Switch

Start Switch

Emergency

Power Switch

Advertising