Bryston MPS2 User Manual

Page 3

Advertising
background image

INTRODUCTION

Thank you for choosing this Bryston product. Bryston

welcomes any suggestions or comments you may have

about our products. We consider you, our customer, to

be Bryston’s most important resource, and your opinion

is very much appreciated.

MPS2 POWER SUPPLY SPECIFICATIONS:

Dimensions: 17” (or 19”) x 2.25” x 11”

Weight:

actual: 15.5 lb. (7.03Kg)

shipping: 19.3 lb. (8.75Kg)

Electrical:

100V~/50-60Hz/100W

110V~/50-60Hz/100W

120V~/50-60Hz/100W

200V~/50-60Hz/100W

220V~/50-60Hz/100W

230V~/50-60Hz/100W

240V~/50-60Hz/100W

Outputs: main outputs:

±37V/250mA

+12V/350mA

remote or switched trigger outputs:

12v @ ≤20mA

GENERAL DESCRIPTION

The MPS2 outboard power supply provides bipolar

DC power for the various Bryston preamps and cross-

overs, including the BP26 series of preamps, the BP1.5

Phono equalization stage and 10B crossovers specifi-

cally designed to be used with external power supplies

(

10B-LR-EPS, 10B-STD-EPS & 10B-SUB-EPS

) .

The MPS2’s power ON/OFF switch is a toggle

switch is located on the front panel along with a green

LED to indicate power ON.

REMOTE ON/OFF FUNCTIONS

When the MPS2 is turned on, any BP26 preamps,

or other Bryston products connected to its 4 main out-

puts, will also be turned on. Also, any other equipment

connected to the MPS2’s remote trigger outputs or

switched remote trigger outputs may also be turned on.

On the rear of the unit there are five 2 pin terminal

blocks that provide control signals for remote on/off

functions. Plug-in screw adjust terminal blocks are

provided for all 5 of these connectors. These terminal

blocks accept bare wires between 12 and 26 AWG.

Insulated wires should be stripped to expose .3 inches

(5/16” or 8mm) of bare wire. Use a small blade screw-

driver (<1/8”) to open and close the wire cages. Do not

overtighten; maximum torque should be 4.5 pound-

inches (0.5N-m) or less.

REMOTE ACTIVATION of OTHER EQUIPMENT VIA THE MPS2

To turn on a Bryston amplifier by turning on the MPS2:

1st) Connect insulated wires from the 2 pin REMOTE

TRIGGER connector on the rear panel of the MPS2

to the two IN terminals on a Bryston power amplifier

remote control connector intended for a 4~14V AC/DC

control signal.

2nd) Put the amplifiers “EXTERNAL TURN ON” switch in

the

EXTERNAL position for the amplifier to respond

to remote control turn-on signals (see figure 2).

To turn a Bryston power amplifier OFF and ON when the

BP26 pre-amp is MUTED and unMUTED respectively:

1st) Connect the

SWITCHED TRIG OUT pins of one of the

MPS2’s 4 outputs to the two

IN terminals on the power

amp’s remote control connector.

2nd) Place the power amplifiers

EXTERNAL TURN ON

switch in the

EXTERNAL position.

Figure 2: Turning SST series power amps on and off via the BP26 MUTE switch

Figure 1: Turning SST series power amps on and off via the MPS2 power supply

Advertising