Page 23 service (cont.) problem, Refill problem: liquid level control overflows, Liquid level control system does not – Bunn DUAL TM (Serial # DUAL010000 - Up) User Manual

Page 23

Advertising
background image

Page 23

SERVICE (cont.)

PROBLEM:

LIQUID LEVEL CONTROL SYSTEM DOES NOT

REFILL

PROBLEM:

LIQUID LEVEL CONTROL OVERFLOWS

RETRY

NO

YES

YES

NO

YES

REPLACE

CONTROL

ASSEMBLY (1)

DRAIN CUP

(4)

OVERFLOW

?

OVERFLOW

?

NO

OVERFLOW

?

REPLACE SOLENOID

VALVE (14)

DRAIN CUP (4)

DISCONNECT WIRE

SOLENOID VALVE (14)

FROM

RETRY

REPLACE PROBE (7)

DRAIN CUP (4)

DISCONNECT PROBE

WIRE FROM PROBE (7)

SHORT PROBE WIRE

TO CHASSIS

RETRY

Liquid Level Control Test Procedure:
1. Disconnect brewer from the power source.
2. With a voltmeter, check the voltage across termi-

nals 3 & 4 of the electronic control assembly (1).
Connect brewer to power source. The indication
must be:
a.) 208 volts ac for three wire 120/208 volt models
and 240 volts ac for three wire 120/240 volt
models.
b.) 200 to 240 volts ac for two wire 200 or 240 volt
models.

ELECTRONIC CONTROL ASSEMBLY (cont.)

P808

P809

BREW START- LOCK

The water must be heated to the preset tempera-

ture indicated by the glowing ready light before a brew
cycle can be initiated.

If the ready light goes out during a brew cycle, the

cycle will continue until it is completed. You must wait
until the ready light glows before starting another brew
cycle.

OVERFLOW CUP FULL

YES

REMOVE POWER

DRAIN CUP

RETRY

NO

DISCONNECT LEVEL PROBE

(4)

(4)

(7)

VOLTAGE PRESENT AT

SOLENOID VALVE

(14)

YES

DOES WATER FLOW

YES

REPLACE PROBE

(7)

NO

NO

REPLACE

SOLENOID VALVE

(14)

REPLACE

CONTROL

ASSEMBLY (1)

27040 041100