Brinkmann GRAND ELITE SERIES 4905 User Manual

Page 11

Advertising
background image

10

Step 10

Loosen nut and detach gas line
from rotisserie burner valve.

NOTE: Bending the hose could

damage the supply line.

Step 11

Carefully pull the gas manifold out
from the burner tubes to allow
access to the thermal couple nut.
Remove thermal couple nut from
the back of the rotisserie burner
valve. Remove the existing LP gas
manifold.

Step 12

Remove two screws on the access
panel located on the back of the
rotisserie burner. Remove panel.

NOTE: Leave panel off until the end

of conversion and all gas
leak testing has been done.

Thermal Couple Nut

Nut

Access Panel Screws

Natural Gas Manifold

Rotisserie Burner Valve

Gas Line

Advertising