Component electrical connections -9 – JLG 10MSP Service Manual User Manual

Page 113

Advertising
background image

SECTION 6 - TROUBLESHOOTING

3121228

– JLG Lift –

6-9

1. Ground Control Module (a)

4. Right Side Battery (b)

7. Power Cable To Right Drive Motor/Brake (a)

2. Left Side Battery (b) (c)

5. Traction Control Module (a)

8. Hydraulic Pump/Motor/Tank Assembly (b)

3. 175 Amp Fuse

6. Power Cable To Left Drive Motor/Brake (a)

Ground Control

P1 - Horn, Alarm, Beacons, Lift Down Valve Harness (a) P4 - Platform Joystick Harness (a)

Module Plugs:

P2 - Elevation/Speed, Charger Limit Switch Harness (a) P5 - Joystick Protocol Harness to Traction Control
P3 - Programmable Security Lock Harness (Option) (a) Module (a)

Notes:

(a) Apply di-electric grease JLG Part Number 3020038 to wiring harness terminals, to prevent moisture from entering module.
(b) Seal NEG (–) and POS (+) posts with battery grease to prevent corrosion.
(c) An quick-disconnect is installed on the left battery (+) POSITIVE cable for easier power disconnect when servicing machine.

(See Figure 6-7.) - This section Troubleshooting for complete machine wiring schematic.

Figure 6-5. Component Electrical Connections.

Advertising