Electrical system – JLG 4017RS Service Manual User Manual

Page 197

Advertising
background image

9-45

3614RS, 4017RS

Electrical System

AUXILIARY

HYDRAULICS –

CURRENT FEEDBACK

READING TOO LOW

33291

5000Ms

Actual auxiliary function A / B (UGM

J3-14) & commanded current

disagree by >125Ma when

command is >250 Ma for 1000Ms

Actual auxiliary A / B current <

225Ma and PWM is >40% for 100ms

Power cycled

REVERSE ALARM AND

LIGHTS – OPEN

CIRCUIT

33210

5000Ms

Open circuit is detected on UGM J1-

1

Power cycled

REVERSE ALARM AND

LIGHTS-SHORT TO

BATTERY

33211

5000Ms

Short to battery is detected on UGM

J1-1

Power cycled

REVERSE ALARM AND

LIGHTS-SHORT TO

GROUND

33212

5000Ms

Short to ground is detected on UGM

J1-1

Power cycled