Shutdown procedure, Fuel reserve / shut-off system – JLG 860SJ Operator Manual User Manual

Page 63

Advertising
background image

SECTION 4 - 3MACHINE OPERATION

3121630

– JLG Lift –

4-3

6.

From Platform, pull Power/Emergency Stop
switch out.

7.

Push the Engine Start switch until engine
starts.

NOTE:

Footswitch must be in released (up) position before starter will
operate. If starter operates with footswitch in the depressed posi-
tion, DO NOT OPERATE MACHINE.

Shutdown Procedure

IF AN ENGINE MALFUNCTION CAUSES AN UNSCHEDULED SHUTDOWN, DETERMINE
THE CAUSE AND CORRECT IT BEFORE RESTARTING THE ENGINE.

1.

Remove all load and allow engine to operate at low speed
for 3-5 minutes; this allows further reduction of internal
engine temperature.

2.

Push Power/Emergency Stop switch in.

3.

Turn Platform/Ground Select switch to Off.

Refer to Engine Manufacturer’s manual for detailed
information.

Fuel Reserve / Shut-Off System

NOTE:

Reference the Service and Maintenance Manual along with a
qualified JLG Mechanic to verify your machine setup.

The Fuel Shutoff System monitors the fuel in the
tank and senses when the fuel level is getting low.
The JLG Control System automatically shuts the
engine down before the fuel tank is emptied unless
the machine is set up for Engine Restart.

If fuel level reaches the Empty range, the Low Fuel
light will begin to flash once a second and there will
be approximately 60 minutes of engine run time
left. If the system is in this condition and automatically shuts
down the engine or if the operator manually shuts down the
engine before the 60 minute run time is complete, the Low Fuel
light will flash 10 times a second and the engine will react accord-
ing to machine setup. Setup options are as follows:

• Engine One Restart - When the engine shuts down, the

operator will be permitted to cycle power and restart the
engine once with approximately 2 minutes of run time.