Bryant DUAL FUEL THERMOSTAT TSTAT User Manual

Page 5

Advertising
background image

4. Press MODE button until EHEAT is displayed. Furnace

should begin to operate within 5 minutes.

D.

Cooling Operation

1. Press MODE button until COOL is displayed under the

mode annunciator.

2. Press down button until display reads 10 degrees below

room temperature. Cooling system should begin to operate
within 5 minutes.

VII.

SELECT DESIRED OPERATION

1. Press FAN button to select AUTO or ON position. Fan

annunciator displays current selection.

2. Press MODE button to select OFF, HEAT, COOL, or

EHEAT. If AUTO is selected, first select heating desired
temperature in HEAT mode and cooling desired tempera-
ture in COOL mode. Refer to homeowner’s guide. Mode
annunciator displays current selection.

3. Press up or down buttons to select desired temperature.

4. If daily cycles are to be programmed now, refer to Home-

owner’s Guide for programming instructions.

5. If thermostat has not been programmed, press HOLD button

to retain desired temperature setting.

NOTE:

If HOLD button is not left ON, temperature setting will

be lost until time/temperature program is entered.

VIII.

CHECKLIST

1. Put away tools and instruments, and clean up debris.
2. Review Homeowner’s Guide with owner.
3. Leave literature packet with owner.

Fig. 2—Single-Stage Furnace with

Single-Speed Heat Pump

A95215

Y/Y2

W/W1

R

24 VAC HOT

FAN

FURNACE

COMPRESSOR

RVS COOLING

N/A

DUAL FUEL

THERMOSTAT

SINGLE-SPEED

HEAT PUMP

24 VAC COM

RVS HEATING

RVS SENSING

OUTDOOR

SENSOR

CONNECTION

G

R

R

W

Y

Y

G

C

C

O/W2

Y1/W2

SINGLE-STAGE

FURNACE

W2

O

OUTDOOR

TEMPERATURE

SENSOR

SEE NOTE 1

S2

S1

L

B

C

Fig. 3—Two-Stage or Variable-Speed Furnace with

Single-Speed Heat Pump

A95216

Y/Y2

W/W1

R

24 VAC HOT

FAN

FURNACE LO

COMPRESSOR

RVS COOLING

FURNACE HI

DUAL FUEL

THERMOSTAT

SINGLE-SPEED

HEAT PUMP

24 VAC COM

RVS HEATING

RVS SENSING

OUTDOOR

SENSOR

CONNECTION

S2

S1

L

B

G

R

R

Y

G

C

C

C

O/W2

Y1/W2

TWO-STAGE OR

VARIABLE SPEED

FURNACE

W2

O

SEE NOTES 1 AND 2

W/W1

Y/Y2

O

W2

Y1

OUTDOOR

TEMPERATURE

SENSOR

A95217

Fig. 4—Single-Stage Furnace with

2-Speed Heat Pump

Y/Y2

W/W1

R

24 VAC HOT

FAN

FURNACE

COMPRESSOR HI

RVS COOLING

COMPRESSOR LO

DUAL FUEL

THERMOSTAT

TWO-SPEED

HEAT PUMP

24 VAC COM

RVS HEATING

RVS SENSING

OUTDOOR

SENSOR

CONNECTION

S2

S1

L

B

G

R

R

W

Y2

Y

G

C

C

C

O/W2

Y1/W2

SINGLE-STAGE

FURNACE

W2

O

SEE NOTE 1

Y1

W3

OUTDOOR

TEMPERATURE

SENSOR

—5—