Bowers & Wilkins CT800 User Manual

Page 21

Advertising
background image

Setting the Subwoofer gain

Disconnect the speakers from the power amplifiers.

Connect the MF/HF power amplifier to the Subwoofer output of the unit.

Set the output level of the oscillator to zero and connect it to the appropriate test input socket.

Set the oscillator frequency to 25Hz.

Set Bank 1 Switch 1 to ON.

Set Bank 4 Switch 2 to ON.

Set Bank 2 Switches 2 & 3 to OFF.

Connect the AC voltmeter to the output terminals of the MF/HF amplifier.

Raise the output level of the oscillator until the meter reads 2 volts.

Substitute the LF power amplifier for the MF/HF power amplifier. Do not alter the output setting of
the oscillator.

Set Bank 4 Switch 2 to OFF.

Adjust the Subwoofer output gain control (C14) until the meter again reads 2 volts.

Configure the dipole lobe for a CT8 DS

Set Bank 3 Switch 3 as required by figure 21 according to the position of the CT8 DS in the system.

Set Bank 3 Switch 2 as desired according to preference and Bank 3 Switch 3 as required by
figure 21.

20

Figure font: Helv 45, 7pt
Figure spacing: 7 x 7 mm

Figure 20

Figure 21

T1

T2

T3

C1

C2

C3

C4

C5

C6

C7

C8

C9

C10 C11

C13

C12

C14

S1

S4

S2

S3

+

+

+

+

Advertising