Removing a connector circuit board assembly – Allen&Heath GL4000 SERVICE MANUAL User Manual

Page 15

Advertising
background image

ALLEN & HEATH

Section A - 10

L4DSM2

REMOVING A CONNECTOR CIRCUIT BOARD ASSEMBLY

Before beginning any service work, remove all power to the console and disconnect any signal cables where necessary.
Service work is best carried out with the console inverted on a clean work surface suitably covered to protect the console
cosmetics. Ensure adequate lighting and use the correct tools. Access to the connector circuit boards is as follows:

1.) With the console inverted, remove the base. Identify which connector board is to be removed and then

disconnect the flat flexible cables and ribbon harnesses to it.

2.) Working from the rear of the console remove the screws (A) fixing the XLR connectors to the panel but do

not remove the screws (B) fixing the panel to the chassis. Remove the 12mm hex jack nuts (C) with a suitable
tool.

3.) The circuit board assembly can now be removed from the rear panel.

NOTE: if removing a master connector circuit board assembly, unscrew the green earth wires connecting the

circuit board assembly to the chassis extrusion before lifting the circuit board clear.

When all service work is complete, remove all debris such as solder, component legs and wire clippings from inside the
console and check your work carefully before reassembly. To refit the connector circuit assembly follow the above
procedure in reverse order. Make sure all harnesses are correctly aligned and plugged on. Test for correct operation.

GL4000-824 inverted with the base cover removed.

CONSOLE FRONT

GL4000 Rear Panel View.

B

B

A

A

C

C

C

C

INPUT SECTION

MASTER SECTION

INPUT SECTION

INPUT CONNECTOR

CIRCUIT BOARD

ASSEMBLY

INPUT CONNECTOR

CIRCUIT BOARD

ASSEMBLY

MASTER CONNECTOR

CIRCUIT BOARD

ASSEMBLY

INPUT CONNECTOR

CIRCUIT BOARD

ASSEMBLY

Advertising