Rear panel overview, Idr-8 user guide 9 – Allen&Heath iDR-8 User Manual

Page 9

Advertising
background image

iDR-8 User Guide

9

Rear Panel Overview

1 Mains input Use the IEC lead with moulded

mains plug suitable for your local mains voltage.
The protection fuse rating is marked on the rear
panel. The on/off switch is positioned on the rear
panel to prevent accidental operation.

2 Network port RJ45 socket for connection to

an Ethernet network or PC using UTP CAT5 cable.
This port is recommended for configuring the
system with iDR software. The MDI/X switch
selects network or direct to PC operation. The link
LED lights when communication is established.
The TX LED lights when data is communicated.

Note: The RS232, MIDI, SysNet and PL-Anet
control ports are not all available at the same time.
A combination of two is selected using iDR
System Manager. The associated active LED
lights when the port is available.

3 RS232 (MODEM) port This is used for

connection to a modem so that the unit can be
interrogated by a remote PC over a standard
telephone line. It can also be used for system
configuration using iDR System Manager software
but the faster network port is recommended.
Pressing the front panel switch selects either the
front or rear RS232 port.

4 MIDI port Standard opto-isolated MIDI port

with IN, THRU and OUT connectors.

5 SysNet port An RS232 serial port for

communication with third party remote controllers
running the Allen & Heath SysNet protocol.

6 PL-Anet port An RS485 serial port for

communication with a network of Allen & Heath
PL wall plates and remote controllers using CAT5
STP cable.

7 DR-Link port RJ45 socket for control of iDR

audio and logic expander units using CAT5 STP
cable. IN and OUT ports are provided on the
expander units so that the control can be daisy
chained through a system with more than one
expander.

8 Audio expander ports RJ45 sockets for

communicating 8 channel digital audio between
the iDR-8 and its expanders using CAT5 STP
cable. Two cables are required between the
expander and iDR-8, one for the audio, the other
for DR-Link control.

9 Mic/Line inputs Balanced XLR inputs for

microphone and line level sources. Adding the
iDR-in expands the iDR-8 to 16 inputs.

10 Audio outputs Balanced XLR line level

outputs with maximum +18dBu level. Adding the
iDR-out expands the iDR-8 to 16 outputs.

11 Monitor inputs and outputs Balanced TRS

jacks for L and R monitor inputs and outputs.
These provide a line level version of the front
panel stereo headphones output and can daisy
chain through multiple iDR units.

12 Switch closure inputs These are provided

on the iDR-switch. They can be hard wired from
remote wall plate and controller switches and
relays.

13 Open collector logic outputs These are

provided on the iDR-switch. They can be used to
control LEDs, lamps, relays and other devices.

14 Earth terminals These are provided to earth

(ground) the switch and logic output cable
shields.

Use null-modem cable to connect to PC com port

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.

ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.

THIS APPARATUS MUST BE EARTHED.

WARNING

47-63Hz ~ 90W MAX

100 - 240V~

active

RS232 (MODEM)

Complies with UL6500, CSA-E65, EN60065

MONITOR OUT

LINK

TX

Refer to user guide for port selection details

FUSE: T1.6AL

AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

SERIAL NUMBER

Made in the UK by ALLEN&HEATH LIMITED

MONITOR IN

DIGITAL EXPANDER

R

PL-ANET

DR-LINK

L

R

AUDIO OUT

AUDIO IN

THRU

active

MDI/X

NETWORK

MIDI OUT

active

MIDI IN

active

SYSNET PORT

L

OUT 8

OUT 7

OUT 5

LINE OUTPUTS

OUT 6

OUT 4

IN 8

IN 7

IN 5

MIC/LINE INPUTS

IN 6

IN 4

OUT 3

OUT 2

OUT 1

IN 3

IN 2

IN 1

Made in the UK by ALLEN&HEATH LIMITED

AUDIO OUT

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.

ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.

47-63Hz ~ 25W MAX

100 - 240V~

THIS APPARATUS MUST BE EARTHED.

WARNING

SERIAL NUMBER

AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

FUSE: T500mAL

next

OUT DR-LINK

previous

IN

IN 10

Complies with UL6500, CSA-E65, EN60065

IN 16

IN 15

MIC/LINE INPUTS

IN 14

IN 13

IN 11

IN 12

IN 9

AUDIO IN

Made in the UK by ALLEN&HEATH LIMITED

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.

ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.

THIS APPARATUS MUST BE EARTHED.

WARNING

47-63Hz ~ 25W MAX

100 - 240V~

SERIAL NUMBER

FUSE: T500mAL

AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

next

OUT DR-LINK

previous

IN

OUT 10

Complies with UL6500, CSA-E65, EN60065

OUT 16

OUT 15

LINE OUTPUTS

OUT 14

OUT 13

OUT 11

OUT 12

OUT 9

V

G

G

4

3

2

1

G

5

6

7

8

G

12 11 10 9

G

13

14

15

16

G

20 19 18 17

G

21

22

23

24

SWITCH INPUTS

LOGIC OUTPUTS

1

2

3

+

-

4

V

G

V

G

V

G

+

- +

- +

-

5

6

7

+

-

8

+

- +

- +

-

9

10

+

- +

- +

- +

-

11

12

14

+

- +

- +

- +

-

15

16

13

switch

G

opto

+10V

2K2

opto

+

-

V

G

+10V DC max total 500mA

open collector

+24V DC, 200mA max

+10V

FUSE: T500mAL

WARNING

THIS APPARATUS MUST BE EARTHED.

ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.

100 - 240V~

47-63Hz ~ 15W MAX

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

Made in the UK by ALLEN&HEATH LIMITED

Complies with UL6500, CSA-E65, EN60065

OUT

IN

DR-LINK

next

previous

TO AVOID DAMAGE ONLY CONNECT

CAUTION 20V DC

COMPATIBLE REMOTE CONTROL

EQUIPMENT TO THE PL-ANET PORT.

DIGITAL EXPANDER

DIGITAL EXPANDER

Advertising