Free standing

The iDR0 can be operated as a freestanding unit for shelf or floor operation. Check that its plastic

feet are fitted. Ensure adequate air flow around the unit. It must not be covered in any way. Always

stand the unit on a firm flat surface away from any soft furnishings or carpet.

Rack mounting

The iDR0 is designed as a 19 inch rack mount unit and will occupy 2U (3.5 inches) of rack space.

The plastic feet may need to be removed before rack mounting. Retain the feet for future use.

Ensure natural convection of airflow around the unit by allowing good ventilation below, in front of
and behind the unit. Rack equipment known to produce a significant amount of heat should not be

mounted directly below the unit. Forced convection by means of a rack mounted fan-tray may be

desirable in situations where space is restricted and the ambient air temperature is high.

Flight casing

We recommend that you use a professional grade flight case with shock mounted internal rack frame.

Ensure adequate ventilation in front of and behind the unit when it is powered.

Cables

Make sure the cables are not stretched in any way and are routed to avoid becoming kinked or

damaged. Allow enough service loop for access and removal of the unit. Ensure all connectors are

fully plugged in and locked.

CAT5 cables

iLive systems are shipped with 1.8 metre CAT5 cables as standard. Depending on type, cables up to

100 metres (330 feet) may be used for applications where the Surface is positioned remote from the

MiniRack. Cable approved by Digigram for EtherSound use should be sourced. Check the Digigram

web site for further information (www.ethersound.com/technology/compatibility.php). Allen & Heath

can supply an 80 meter drum of suitable cable if needed, part number AH7000. Two of these are
required to connect control and audio between the MiniRack and the Surface. One is required to

connect audio between the MiniRack and another remote rack.

Dimensions

Do not obstruct the ventilation

slots. Ensure adequate air flow around

the iPS10.

Ensure proper grounding. Do not

remove the IEC mains cord earth

(ground) connection.

Do not remove the cover or

modules of the iDR0. There are no

user serviceable parts inside.