WARNING: These products may represent a possible shock or fire hazard if improperly installed or attached in any way.
Products should be installed in accordance with these instructions, current electrical codes and/or the current National
Electric Code (NEC).

Warning: To avoid electric shock, disconnect power prior to installation.
Caution: Injury to persons and damage to the fixture and/or mounting surface may result if the
fixture is pulled from the surface. To reduce the likelihood of such injury or damage, mount
on a surface that is mechanically sound.

1. Pull the lens cover away from the front edge of the fixture gently rotating toward the back of

the fixture. The lens cover will now be open at a 90° angle to the base of the fixture. (Figure 1)

2. Remove the lens cover from housing gently by sliding each end of the lens toward the front of

the unit while holding at 90°, then closing to about 30° and lifting the metal tab up

through the slot in the end cap. (Figure 1, inset)

3. Place fixture in desired location and mark the position of the mounting holes.

4. Set fixture housing aside and start mounting screws at marks leaving a

1

/

4

” space between surface

and screw head.

5. To gain access to wires contained inside the wiring compartment, push the metal “Quick Clips” in

succession with thumb while holding and lifting off the wiring compartment cover. (Figure 2)

6. Locate and remove whichever knockout is most conveniently located to your 120V power supply.

Knockouts are located on the back and the top of the fixture. (Figure 3)

Supply wires connection:

1. Slip fixture housing over mounting screws along keyhole slots where they narrow to hold fixture in

place and allow magnet on front of housing to hold wiring compartment cover up for “hands-free”

wiring.

2. Tighten mounting screws to secure housing in place.

3. Install cable connecter that is appropriate for the supply wire following National Electric Code and

local codes.

4. Install cable following National Electric Code and local building code requirements. AC supply

should be 120V protected by circuit breaker or fuse.

5. Connect line voltage AC supply wire(s) (Black) to the line voltage AC wire(s) (Black) inside the

fixture. Secure the connection using the quick connector provided.

6. Connect the neutral AC supply wire(s) (White) to the neutral AC wire(s) White inside the fixture.

Secure the connection using the quick connector provided.

7. Connect the ground AC supply wire(s) (Green or bare wire) to the ground AC wire(s) (Green) inside

the fixture. Secure the connection using the quick connector provided. If your system has no

ground wire, you should consult a qualified electrician before proceeding with the installation.

Note: Electric shock, overheating, low or no light output and shortened lamp life can result if

proper grounding is not done.

8. Insure that no wires are exposed after making the electrical connections.

9. Arrange the wires inside the fixture so they will fit under the wiring compartment cover.

10. Take wiring compartment cover from magnet’s hold and tilt it so that back edge slides under back

lip of housing. Push wiring compartment cover firmly until it snaps into place, held by the metal

“Quick Clips”. Note: Be sure that the wires are not pinched or damaged by any part of the housing

or the cover.

Install the T2 lamp provided:

Fluoresent T2 (replacement lamp is 043T-F06/30 for 10”,

043T-F08/30 for 14”, 043T-F13/30 for 22”, 043T-F18/30 for 28” and 043T-F24/30 for 32”). Make sure

power is off. Line up narrowed ends of lamp vertically to align with socket. Gently press lamp into

socket until seated. CAUTION: T2 lamp is fragile. Do not press or pull lamp in middle. Handle only at

each end.

Replace the lens cover:

See Figure 1. While holding the lens cover at 90° to the fixture, insert

the small metal tab of the lens cover that corresponds to the non-slotted holding area into place first.

Close the 90° angle to about 30° and align the other small metal tab with the slot on the other end and

insert. Gently push the sides of the lens toward the back of the unit until the lens holding tabs snap

into place. Close the cover by rotating the lens 90° until it snaps tightly to magnetic closure. Do not

operate without lens cover in place.

120 Volt PRIORI Series T2 Under Cabinet Light

Installation Instructions for 043T Hardwire Series using line voltage

ADDITIONAL SAFETY MEASURES:

1. Lamp becomes hot quickly. Let lamp cool before replacing.

2. Do not touch hot lens, lens holder or housing. Only contact switch when turning on or off fixture.

3. Do not look directly at lighted bulb.

4. Keep lamp away from flammable materials.

5. Do not operate lamp with missing or damaged lens.

6. Do not operate without end connector covers in place for any end ports not in use.

RV1112-KB

lens cover

Figure 1

Figure 2

Wiring compartment cover

Push “Quick Clips” with

thumb to remove cover.

magnet

appx 30

°

appx 90

°

Guide metal
tab through
slot in the end cap
to remove lens cover.

Figure 3

Conduit connector

Knockouts

Keyhole slot

End connector
cover

Remove cover to access

wiring compartment.