Component chart, Gabled-hip end frame, Gabled-hip end units – Anchor NAVI-TRAC LITE 30 WIDE User Manual

Page 15

Advertising
background image

15

APPENDIX #1

(GABLED-HIP) AND

(GABLED-GABLED) END UNITS

GABLED-HIP END
FRAME

In the Hip-Gable construction, the hip end should be built first
to provide stability to the structure. Then, using the same tech-
niques as shown earlier, continue standing middle beams as
desired.

At the final end beam, be sure to attach the Gabled End Rafter
Fittings and the End Uprights themselves before standing the
beam (see fig. 48)

Notice that all 30’ wide Gabled ends require the X-cabling of the
end bay (see fig. 47). Also, when the structure exceeds 60 ft
of length, and additional X-Cabled bay is required (see fig. 58).
Parts for the Gabled End construction are listed below. For
assembly procedure, see the top of page 20.

GABLED-HIP END UNITS

47

X-Cabling stabilizes
the Gabled End Bay

COMPONENT CHART

PARTS FOR 30’ HIP-GABLED

PER

PER

LABEL

OR GABLED-GABLED UNITS

30’

10’

(LETTER

(GABLED COMPONENTS IN ITALICS)

POSITION

ID

PART

GBL END

EXTENSION MID

ON DWG)

COMPONENT DESCRIPTION

CODE

CODE

#

KIT (#1358)

KIT (#1356)

TOP EXTRUSIONS WITH CHANNELS:

E-15

EAVE - 15’

8004410

0

2

RG-15

RIDGE W/ HOOKS - 15’

8004415

0

1

R-30

RAFTER 30’

WHITE BRACE HOLE

8004440

0

2

EE-10

GABLED END MID EAVE - 10’

8004475

1

0

EW-10

GABLED END WING EAVE - 10’

8004460

2

0

GU

GABLED END UPRIGHT W/ TOP FITTING

8004465

2

0

PURLINS AND BRACES:

P-10

PURLIN

,

10

’ [

For 30’ Clearspans & Reduced Bays only

]

80410

0

[2]

P-15

PURLIN, 15’

80420

0

2

RB

RIDGE BRACE

3580660

0

1

GRB

GABLED END RIDGE BRACE

3580662

1

0

UPRIGHTS:

U-8

UPRIGHT - 8’

8004450

0

2

WELDMENTS, FITTINGS & PLATES:

BA

BASEPLATES, ADJUSTABLE, 2-HOLED

8004505

0

2

BAG

BASE PLATE, GABLED END, ADJ, 2-HOLED

8004510

2

0

RW

RIDGE WELDMENTS ASSEMBLY

8004545

0

1

EW

EAVE WELDMENT W/ PINS

8004530

0

2

GWL

GABLED END WELDMENT (L)

8004535

1

0

GWR

GABLED END WELDMENT (R)

8004540

1

0

GRFL & R

GABLED END RAFTER FITTINGS [L & R]

8004470

1 PAIR

0

TP

TENSION LOCK PIN

3102865

2

2

CABLES

X8-15

X-CABLE, 8’ UPRIGHT 15’ BAY

GREEN

NAVLTCS-BAY15-U8 8004560

4

0 (unless over 60’ L)

X9-15

X-CABLE, 9’ UPRIGHT 15’ BAY (FOR CS ONLY)

GREEN

NAVLTCS-BAY15-U9 8004590

[4]

0

X10-15 X-CABLE, 10’ UPRIGHT 15’ BAY (FOR CS ONLY)

GREEN

NAVLTCS-BAY15-U10 8004500

[4]

0

XR-15

X-CABLE, RAFTER, 15’ BAY

BLUE

NAVLT-BAY15

8004570

4

0

*

*

The top fitting on the GU must be slid out of the upright so it is pinned in the second hole.