1-3

FIGURE 1.1 PARTS LISTING

1.2

Names of Parts

1.3

Prior to Operation

When the pump is delivered, first perform the following
checks:

Inspection
While unpacking, inspect the product for damage
during shipment, and make sure all bolts and nuts are
tightened properly.

Specification check
Check the model number to make sure it is the product
that was ordered. Be certain it is the correct voltage
and frequency.

Note:

If there is any problem with the product as
shipped, contact your nearest dealer or TSURUMI
representative at once.

• Application Specifications

WARNING

!

DO NOT operate this product under any conditions
other than those for which it is specified. Failure to
observe this precaution can lead to electrical
shock, electrical leakage, fire, water leakage or
other problems.

Check with your local Tsurumi Distributor to verify the
operating conditions fall within the conditions listed on
the Name Plate.

T

SURUMI

P

UMP

WARNING

!

1.5

Standard Specifications (60 Hz)

Note:

The weight (mass) given above is the operating weight of the pump itself, not including the power cable.

1.4

Major Standard Specifications

Applicable Liquids,

Pond Water, Ground Water

Consistency and
Temperature

32–104°F (0–40°C)

Pump

Impeller

Semi-Vortex Type

Shaft Seal

Double Mechanical Seal

Bearing

Shielded Ball Bearing

Motor

Specification

Dry Submersible Induction Motor (2-pole)

Insulation

Class E

Protection System (Built-In)

Miniature Protector

Lubricant

White Mineral Oil ISO VG32

Discharge Connection

NPT 2"

Note:

Consult your local dealer or TSURUMI representative before using with any liquids other than those indicated
in this document.

If the pump is used to drain a swimming pool, the
pump must be connected to a Ground Fault
Interrupter (GFI).

If the pump is used in fountains, the pump must be
connected to a Ground Fault Interrupter (GFI).

The pump must not be used when people are in
the water.

Proper plug must be provided according to local
codes and standards. Refer to wiring diagram.

DO NOT use this pump in liquids other than water,
such as oil, salt water, or organic solvents.

Bore

Rated

Max. Head

Max. Capacity

Weight

(inch)

Current

(ft.)

(GPH)

(lbs)

(mm)

(A)

(m)

(m

3

/min)

(kg)

2

3.1

13.8

3000

12.8

50

120 V

4.2

0.19

5.8

Model

3-PL

Capacitor-Run

Starting Method

320

Input Watts

1

Phase

1- 4

Impeller

Pump Casing

Oil Casing

Mechanical Seal

Oil

Power Cable

Lifting Handle

Oil Plug

Oil Lifter

Rubber Cushion

PL

DO NOT use in water temperatures outside the range
of 32–104°F (0–40°C) which can lead to failure,
electrical leakage or shock.

DO NOT use in the vicinity of explosive or
flammable materials.

Use only in fully assembled state.

T

SURUMI

P

UMP

MAKE SURE the power supply voltage agrees with
the rated voltage on the Name Plate.
Maximum voltage at the pump cannot exceed
126 V. Minimum Voltage at the pump cannot be
less than 105 V.

PL