Atop Technology SW550X Installation Guide User Manual

Hardware installation guide, Atop technologies, inc, Industrial wireless serial device server

Advertising
background image

Industrial Wireless Serial Device Server

Hardware Installation Guide

Version 1.0

Updated on June, 2012

Technologies

Tel: 886-3-5508137

Fax: 886-3-5508131

www.atop.com.tw

P/N: 89900409G

SW550X Series

Atop Technologies, Inc.

Installation Overview

Field Maintenance and Service

The device’s appearance is as in the figure below.

There are mounting plates and screws that come

inside the package. Proceed to place the screws

on the back of the device as shown in (Fig. 1).

Next we can then proceed to connect the device to the LAN (switch or

PC, depending on the case), take care on using an RJ45

terminal/connector; after this we can then proceed to the device’s

settings.

Other points to take into consideration when installing the device follow next.

The antennas are 3dBi (at 2.4 GHz) and a 5 dBi (at 5GHz); once fixed

to the rail, do not place them parallel, otherwise their signal will

interfere with each other.

Note:

The first two pictures illustrate

not recommended setup for the SW550X;

signal will strongly decrease with the antennas on this position.

Proceed then to fix the antennas to the female

RP-SMA connectors deemed to, (Fig. 3).

You can then choose whether to place the terminal

block at this point or do it later depending on the

actual location of the device or level of comfort for

performing such operation.

(Fig. 3)

(Fig. 2)

1.

2.

5.

3.

Once the plate has been firmly put in place,

proceed to mount the whole device as shown in

(Fig. 4).

Proceed to (Fig. 5) if you want

to remove the device from

DIN-Rail.

4.

If the device is not going to be placed on

the rail and to be positioned horizontally,

then the antennas could be setup making

a “V” shape,(Fig. 6).

The openings to the sides are for the device’s heat dissipation and

there may be inside hazardous voltages, please never obstruct or

cover them with any objects or try to

insert them through it.

SW550X’s factory IP by default is 10.0.50.100 you can access the

device by its Web UI once it is connected to a physical network (or

using Serial Manager, for more information on Serial Manager,

please refer to the manual, Chapter 3). Please be aware that the PC

needed for this procedure needs to be in the same subnet, or you

may refer yourself to the User’s Manual on Sec. 3.1.

If the device requires servicing of any kind, you may need to disconnect

and remove it from its mounting. The initial installation should be done

in a way that makes this as convenient as possible.

Voltage/Power lines should be properly insulated as well as other

cables. Be careful when handling them so as to not trip over.

Do not under any circumstance insert foreign objects of any kind into

the heat dissipation holes located in the different faces of the device.

This may not only harm the internal layout but might cause harm to

you as well.

Do not under any circumstance open the device for any reason.

Please contact your dealer for any repair needed or follow the

instructions on section of your User’s manual.

(Fig. 4)

(Fig. 5)

There is a screw close to the power terminal

block this screw is used to connect the grounding

of the SW550X.

Although internal grounding has been done

inside, in order to ensure overall maximum

performance and protect your device it is still

strongly advised to link this point to the ground as

well; hazardous ESD can come into contact with

it and damage your equipment. On the terminal

block, there is a terminal for Frame Ground, you

can choose whether to connect it the grounding,

you may opt between only one of these two

grounds ( the one chosen should be connected at

all times).(Fig. 2)

(Fig. 1)

(Fig. 6)

Package Check List

Pin Assignments

Optional Accessories

Inside the package you will find the following items:

Industrial Wireless Serial Device Server SW550X x 1

3 ~ 5 dBi antenna x 2

3-Pin 5.08mm Lockable Terminal Block x 1

5-Pin 5.08mm Lockable Terminal Block x 1

(for SW5501-TB, SW5501-Sis)

5-Pin 5.08mm Lockable Terminal Block x 2

(for SW5502-TB, SW5502-Sis)

Din Rail Kit x 1 (Already mounted to the device)

Installation Guide + Warranty Card x 1

CD (User’s Manual / Installation Guide / Serial Manager Utility) x 1

Item

Description

US315-12 (US-Y)
Power Adapter

Y-Type (5.08 mm) power adaptor,
100-240VAC input, 1.25A @ 12VDC output,
US plug

USE315-12 (EU-Y)
Power Adapter

Y-Type (5.08 mm) power adaptor,
100-240VAC input, 1.25A @ 12VDC output,
EU plug

ADP-DB9(F)-TB5

Female DB9 to Female 3.81 TB5 Converter

WMK-454-Black

Black Aluminum Wall Mount Kit

5-pin Terminal Block for RS-422/485

Pin

1
2
3
4
5

RS-422

TXD+

TXD-

RXD+

RXD-

SG

RS-485

N/A
N/A

DATA+

DATA-

SG

1 2 3 4 5

1 2 3 4 5

9-pin D-sub Connector for RS-232/422/485

Pin

1
2
3
4
5
6
7
8
9

RS-232

DCD
RXD

TXD
DTR

SG

DSR

RTS
CTS

RI

RS-485

N/A
N/A

DATA+

N/A

SG

N/A

DATA-

N/A

N/A

RS-422

N/A

TXD+

RXD+

N/A

SG

N/A

RXD-

TXD-

N/A

1 2 3 4 5

6 7 8 9

F.G

V-

V+

ON

SAB

1

2

3

100

80

60

40

20

COM1

COM2

ANT1

ANT2

LAN

Reset

COM1

Status

Tx

Rx

RUN

COM2

WLAN

COM
RUN

ON SAB

1

2

3 4 5

6

F.G

V-

V+

ON

SAB

1

2

3

100

80

60

40

20

COM1

COM2

ANT1

ANT2

LAN

Reset

COM1

Status

Tx

Rx

RUN

COM2

WLAN

COM

RUN

ON SAB

1

2 3 4 5 6

F.G

V-

V+

ON

SAB

1

2

3

100

80

60

40

20

COM1

COM2

ANT1

ANT2

LAN

Reset

COM1

Status

Tx

Rx

RUN

COM2

WLAN

COM
RUN

ON SAB

1

2 3 4

5

6

ON

SAB

12

3

100

80

60

40

20

COM1

COM2

ANT1

ANT2

LAN

Reset

C

O

M

1

Status

T

x

R

x

R

U

N

C

O

M

2

W

LA

N

CO

M

RU

N

ON SAB

1 2 3 4

5 6

ON

SAB

12

3

100

80

60

40

20

COM1

COM2

ANT

1

ANT

2

LA

N

Re

set

C

O

M

1

Status

T

x

R

x

R

U

N

C

O

M

2

W

LA

N

CO

M

RU

N

ON SAB

1 2 3 4 5 6

F.G

V-

V+

ON

SAB

1

2

3

100

80

60

40

20

COM1

COM2

ANT1

ANT2

LAN

Reset

COM1

Status

Tx

Rx

RUN

COM2

WLAN

COM
RUN

ON SAB

1

2 3 4

5

6

F.G

V-

V+

ANT1

ANT2

COM

RUN

ON

SAB

1

2 3

F.G.

V-

V+

Advertising