Power-up, Probe installation – Auto Meter 880017 User Manual

Page 2

Advertising
background image

power-Up

The pointer will move backward to the stop pin and then display actual temperature. This procedure is an auto-calibration function and is

performed on every power-up. While this test is being performed, the gauge may make a clicking sound. This is normal.

12 mONTH LImITED WARRANTy

Auto Meter Products, Inc. warrants to the consumer that all Auto Meter High Performance products will be free from defects in material and workmanship for a period of twelve (12) months from date of the

original purchase. Products that fail within this 12 month warranty period will be repaired or replaced at Auto Meter’s option to the consumer, when it is determined by Auto Meter Products, Inc. that the product

failed due to defects in material or workmanship. This warranty is limited to the repair or replacement of parts in the Auto Meter instruments. In no event shall this warranty exceed the original purchase price of

the Auto Meter instruments nor shall Auto Meter Products, Inc. be responsible for special, incidental or consequential damages or costs incurred due to the failure of this product. Warranty claims to Auto Meter

must be transportation prepaid and accompanied with dated proof of purchase. This warranty applies only to the original purchaser of product and is non-transferable. All implied warranties shall be limited in

duration to the said 12 month warranty period. Breaking the instrument seal, improper use or installation, accident, water damage, abuse, unauthorized repairs or alterations voids this warranty. Auto Meter

Products, Inc. disclaims any liability for consequential damages due to breach of any written or implied warranty on all products manufactured by Auto Meter.

FOR SERVICE SEND TO: AUTO mETER pRODUCTS, INC. 413 W. Elm St., Sycamore, IL 60178 USA (815) 899-0801

Email us at [email protected]

http://www.autometer.com

2650-1131 2/23/06

pROBE INSTALLATION

1. Begin by installing the thermocouple in the exhaust, then work back to the gauge. Installing the probe in the proper location will

insure optimal temperature readings. For non-turbo engines, install the probe 1-2 inches from the cylinder head.

For turbo engines, remove the exhaust manifold and install the probe 1-2 inches from the cylinder head. If the exhaust manifold

can not be removed, install the probe 1-2 inches after the turbo exhaust outlet (Exhaust gas temps could drop over 200˚ when

installing after the turbo). CLEAN ALL METAL FILINGS out of the exhaust manifold. Metal filings will damage the turbo impellor

if they go through the turbo.

The probe can be mounted in two different ways, so please use the method best suited for your needs.

A) Pre-existing

1

/

8

” NPT Threaded Hole: Simply screw the threaded fitting into the hole, insert the probe, and tighten the set

screw snugly onto the probe. (Caution: do not over tighten set screw or damage to probe may occur.) Make sure the probe is

oriented so the wires do not come in contact with, or become too close to the manifold or other hot engine parts.

See illustration for details.

B) Stainless Clamp Method: This method is for applications that require frequent removal of the manifold or header for service,

or just faster and easier installation. Drill a

7

/

16

” diameter hole about 6” down from the junction of the exhaust pipe to manifold

junction. Undo the clamp and slide the probe into the hole in the clamp. Slide the set screw collar onto the probe.

Before tightening the collar in position make sure that when inserted, the probe will have it’s tip in the middle two-thirds of the

exhaust stream. Tighten screw collar in position. (Caution: do not over tighten set screw or damage to probe may occur.)

Hold the clamp open when inserting the probe into the

13

/

32

” hole. Re-join the clamp ends and tighten in position.

Make sure the probe is oriented so the wires do not come in contact with, or become too close to the manifold or other hot

engine parts. See the illustration below for details.

2. With the probe installed, the wire harness can now be routed to the gauge. The wire harness is an integral part of the pyrometer

calibration. It may not be shortened or lengthened without affecting the gauge calibration. You will need to determine a suitable

location to coil the excess wire, and tie it loosely with a wire tie. (Loosely tying the excess coil prevents embritlement caused by

vibration.) Pass the harness through the fire wall using an existing hole, or drill a 1” diameter hole and use the rubber grommet

provided to protect the wire from damage.

PROBE

SET SCREW

COLLAR

STAINLESS

CLAMP

SET SCREW

1/8” NPT FITTING

middle 2/3

A. pre-existing 1/8” NpT Threaded Hole

B. Stainless Clamp method

© 2006 Auto Meter Products, Inc.

The Super Bezel is a registered trademark of Auto Meter Products, Inc.

SERVICE

For service send your product to Auto Meter in a well packed shipping carton. Please include a note explaining what the problem is along with your phone number. Please specify when you need

the product back. If you need it back immediately mark the outside of the box “RUSH REPAIR,” and Auto Meter will service product within two days after receiving it. ($10.00 charge will be added

to the cost of “RUSH REPAIR.”) If you are sending product back for Warranty adjustment, you must include a copy (or original) of your sales receipt from the place of purchase.