Power-up, Warning indicator, Peak recall – Auto Meter 7963 User Manual

Page 2: Installation - nitrous pressure

Advertising
background image

power-Up

The pointer will move backward to the stop pin and then move to the zero box. This procedure is an auto-calibration

function and is performed on every power-up. While this test is being performed, the gauge may make a clicking sound.

This is normal.

12 MONTH LIMITeD wARRANTY

Auto Meter Products, Inc. warrants to the consumer that all Auto Meter High Performance products will be free from defects in material and workmanship for a period of twelve (12) months from date of the

original purchase. Products that fail within this 12 month warranty period will be repaired or replaced at Auto Meter’s option to the consumer, when it is determined by Auto Meter Products, Inc. that the product

failed due to defects in material or workmanship. This warranty is limited to the repair or replacement of parts in the Auto Meter instruments. In no event shall this warranty exceed the original purchase price of

the Auto Meter instruments nor shall Auto Meter Products, Inc. be responsible for special, incidental or consequential damages or costs incurred due to the failure of this product. Warranty claims to Auto Meter

must be transportation prepaid and accompanied with dated proof of purchase. This warranty applies only to the original purchaser of product and is non-transferable. All implied warranties shall be limited in

duration to the said 12 month warranty period. Breaking the instrument seal, improper use or installation, accident, water damage, abuse, unauthorized repairs or alterations voids this warranty. Auto Meter

Products, Inc. disclaims any liability for consequential damages due to breach of any written or implied warranty on all products manufactured by Auto Meter.

SeRVICe

For service send your product to Auto Meter in a well packed shipping carton. Please include a note explaining what the problem is along with your phone number. Please specify when you

need the product back. If you need it back immediately mark the outside of the box “RUSH REPAIR,” and Auto Meter will service product within two days after receiving it. ($10.00 charge will be

added to the cost of “RUSH REPAIR.”) If you are sending product back for Warranty adjustment, you must include a copy (or original) of your sales receipt from the place of purchase.

FOR SERVICE SEND TO: AUTO MeTeR pRODUCTS, INC. 413 W. Elm St., Sycamore, IL 60178 USA (866) 248-6357

Email us at [email protected]

www.autometer.com

© 2009 Auto Meter Products, Inc.

The Super Bezel is a registered trademark of Auto Meter Products, Inc.

Warning Indicator

To adjust the warning set point, momentarily press & release the WARN (W) button. The warning light will begin to flash and the pointer will move to the
previous set point signifying that warning set mode has been selected. Once in set mode, press the WARN (W) button to move the pointer down, or press
the PEAK (P) button to move the pointer up. Warning set points can only be set in the pressure range. Three seconds after the last button press, the
warning light will stop blinking & the pointer will return to the current pressure reading. The warning set point is retained when power is removed
from the gauge.

Peak Recall

Press and hold the PEAK (P) button to recall the highest pressure reading since the memory was last cleared. To clear the memory, press & hold the PEAK
(P) button, and while still holding the PEAK (P) button, press the WARN (W) button. The pointer will move to 0 psi to indicate that the memory has been
cleared. Release the PEAK (P) & WARN (W) buttons to resume normal operation. The peak recall point is retained when power is removed from the gauge.

2650-1436-00 5/7/09

Installation - Nitrous pressure

1. Check that you have all parts required for installation, and the

engine is cool.

2. Disconnect the negative (-) battery cable.

3. Gauge mounts in a 2

1

16

” hole for 2

1

16

” gauges, & a 2

5

8

” hole for

2

5

8

” gauges. Use supplied brackets & nuts to secure gauge to dash.

4. Drill 1” diameter hole where wires pass through sheet metal (such

as firewall) and install rubber grommet provided.

5. Connect the white wire to dash lighting or switchable 12v light

source, the red wire to switched +12V source and the black wire to

ground. (see diagram for details)

6. Make sure the nitrous bottle valve is closed and there is no

pressure in the system.

7. Remove the main nitrous feed line from the bottle or the nitrous

solenoid. Install the in-line gauge adapter either on the nitrous

bottle or nitrous solenoid. Re-install the main nitrous feed line.

Install pressure sender and wiring harness. For mounting off bottle

in rear of car, use 20’ sender harness model 5223.

8. Open the nitrous bottle valve.

NOTe: Test all fittings and hoses for any leakage. If any leaks are

detected, determine the cause of the leak and repair. Do not

operate vehicle if any leaks are detected.

In-Line

Gauge Adapter

Nitrous

Solenoid

IN

OUT

Main Nitrous Feed

Nitrous

Bottle

Use teflon sealing

compound where

symbol indicates.

(Tape not

recommended on

these threads.)

Check with

your nitrous kit

manufacturer

for availability

of this adapter.